home *** CD-ROM | disk | FTP | other *** search
/ InfoMagic Standards 1994 January / InfoMagic Standards - January 1994.iso / ccitt / 1988 / troff / 6_9_09.tro < prev    next >
Text File  |  1991-12-13  |  95KB  |  6,120 lines

  1. .rs
  2. .\" Troff code generated by TPS Convert from ITU Original Files
  3. .\"                 Not Copyright ( c) 1991 
  4. .\"
  5. .\" Assumes tbl, eqn, MS macros, and lots of luck.
  6. .TA 1c 2c 3c 4c 5c 6c 7c 8c
  7. .ds CH
  8. .ds CF
  9. .EQ
  10. delim @@
  11. .EN
  12. .nr LL 40.5P
  13. .nr ll 40.5P
  14. .nr HM 3P
  15. .nr FM 6P
  16. .nr PO 4P
  17. .nr PD 9p
  18. .po 4P
  19.  
  20. .rs
  21. \v | 5i'
  22. .sp 2P
  23. .LP
  24. \fBRecommendation\ Q.783\fR 
  25. .RT
  26. .sp 2P
  27. .sp 1P
  28. .ce 1000
  29. \fBTUP\ TEST\ SPECIFICATION\fR 
  30. .EF '%    Fascicle\ VI.9\ \(em\ Rec.\ Q.783''
  31. .OF '''Fascicle\ VI.9\ \(em\ Rec.\ Q.783    %'
  32. .ce 0
  33. .sp 1P
  34. .LP
  35. \fB1\fR     \fBIntroduction\fR 
  36. .sp 1P
  37. .RT
  38. .PP
  39. This Recommendation contains a set of detailed tests for the
  40. Signalling System\ No.\ 7 Telephony User Part (TUP). These tests are intended 
  41. to validate the protocol specified in Q.721\(hyQ.724\ Recommendations. 
  42. This 
  43. Recommendation conforms to Q.780\ Recommendations which describes the basic
  44. rules of the test specification.
  45. .RT
  46. .sp 2P
  47. .LP
  48. \fB2\fR     \fBGeneral principles of TUP tests\fR 
  49. .sp 1P
  50. .RT
  51. .PP
  52. The TUP tests aim at testing TUP protocol conformance in a given
  53. implementation. The tests are described as \*QValidation\*U tests or \*QValidation\*U 
  54. and \*QCompatibility\*U tests. Each test description indicates in the field 
  55. \*Qtype of test\*U whether the test is \*QValidation\*U or \*QValidation\*U 
  56. and \*QCompatibility\*U. As the TUP also describes the required call control 
  57. actions resulting from TUP message transfer the TUP tester also checks 
  58. the result of those call control 
  59. actions, e.g.\ that speech/information transfer is possible.
  60. .RT
  61. .sp 2P
  62. .LP
  63. \fB3\fR     \fBTest configuration\fR 
  64. .sp 1P
  65. .RT
  66. .PP
  67. A stable signalling relation is required between \*QSP A\*U and \*QSP B\*U 
  68. in order to effectively test the TUP. In addition telephony circuits are 
  69. required for some of the tests.
  70. .RT
  71. .sp 2P
  72. .LP
  73. \fB4\fR     \fBTUP test list\fR 
  74. .sp 1P
  75. .RT
  76. .PP
  77. All tests may be validation tests. Tests marked \*Q*\*U are
  78. compatibility tests. Tests marked \*Qfs\*U are for further study.
  79. .RT
  80. .sp 2P
  81. .LP
  82. .sp 1
  83.     1
  84.     \fICircuit supervision\fR 
  85. .sp 1P
  86. .RT
  87. .sp 1P
  88. .LP
  89. *
  90.     1.1
  91.     Non allocated circuits
  92. .sp 9p
  93. .RT
  94. .sp 1P
  95. .LP
  96.     1.2
  97.     Reset of circuits
  98. .sp 9p
  99. .RT
  100. .LP
  101.     1.2.1
  102.     RSC received on an idle circuit
  103. .LP
  104.     1.2.2
  105.     RSC sent on an idle circuit
  106. .LP
  107.     1.2.3
  108.     Group reset received
  109. .LP
  110.     1.2.4
  111.     Group reset sent
  112. .sp 1P
  113. .LP
  114.     1.3
  115.     Blocking of circuits
  116. .sp 9p
  117. .RT
  118. .LP
  119.     1.3.1
  120.     Group blocking/unblocking
  121. .LP
  122.     1.3.1.1
  123.     HGB received
  124. .LP
  125.     1.3.1.2
  126.     HGB sent
  127. .LP
  128. *
  129.     1.3.1.3
  130.     MGB received
  131. .LP
  132. *
  133.     1.3.1.4
  134.     MGB sent
  135. .LP
  136.     1.3.2
  137.     Circuit blocking/unblocking
  138. .LP
  139. *
  140.     1.3.2.1
  141.     BLO received
  142. .LP
  143. *
  144.     1.3.2.2
  145.     BLO sent
  146. .LP
  147. *
  148.     1.3.2.3
  149.     Circuit blocking from both ends; removal of
  150. blocking from one end
  151. .LP
  152.     1.3.2.4
  153.     Interruption for FDM circuits
  154. .bp
  155. .sp 1P
  156. .LP
  157.     1.4
  158.     Continuity check test call
  159. .sp 9p
  160. .RT
  161. .LP
  162. *
  163.     1.4.1
  164.     CCTC received: successful
  165. .LP
  166. *
  167.     1.4.2
  168.     CCTC sent: successful
  169. .LP
  170.     1.4.3
  171.     CCTC received: unsuccessful
  172. .LP
  173.     1.4.4
  174.     CCTC sent: unsuccessful
  175. .sp 1P
  176. .LP
  177.     1.5
  178.     Receipt of unreasonable signalling information
  179. .sp 9p
  180. .RT
  181. .LP
  182.     1.5.1
  183.     Received
  184. .sp 2P
  185. .LP
  186.     2
  187.     \fINormal call set\(hyup\fR 
  188. .sp 1P
  189. .RT
  190. .sp 1P
  191. .LP
  192.     2.1
  193.     Both way circuit selection
  194. .sp 9p
  195. .RT
  196. .LP
  197. *
  198.     2.1.1
  199.     IAM sent by controlling SP
  200. .LP
  201. *
  202.     2.1.2
  203.     IAM sent by non controlling SP
  204. .sp 1P
  205. .LP
  206.     2.2
  207.     Called address sending
  208. .sp 9p
  209. .RT
  210. .LP
  211. *
  212.     2.2.1
  213.     \*Qen bloc\*U operation
  214. .LP
  215. *
  216.     2.2.2
  217.     Overlap operation
  218. .sp 1P
  219. .LP
  220.     2.3
  221.     Successful call set\(hyup
  222. .sp 9p
  223. .RT
  224. .LP
  225.     2.3.1
  226.     Ordinary call (with various ACM and ANS)
  227. .LP
  228. *
  229.     2.3.2
  230.     Call switched via satellite
  231. .LP
  232. *
  233.     2.3.3
  234.     Test for echo suppressor call set\(hyup
  235. .LP
  236. *
  237.     2.3.4
  238.     Blocking and unblocking during a call (initiated)
  239. .LP
  240. *
  241.     2.3.5
  242.     Blocking and unblocking during a call (received)
  243. .sp 2P
  244. .LP
  245.     3
  246.     \fINormal call release\fR 
  247. .sp 1P
  248. .RT
  249. .sp 1P
  250. .LP
  251. *
  252.     3.1
  253.     Calling party clears: before ACM
  254. .sp 9p
  255. .RT
  256. .sp 1P
  257. .LP
  258. *
  259.     3.2
  260.     Calling party clears: before ANS
  261. .sp 9p
  262. .RT
  263. .sp 1P
  264. .LP
  265. *
  266.     3.3
  267.     Calling party clears: after ANS
  268. .sp 9p
  269. .RT
  270. .sp 1P
  271. .LP
  272. *
  273.     3.4
  274.     Calling party clears: after CLEAR BACK
  275. .sp 9p
  276. .RT
  277. .sp 1P
  278. .LP
  279. *
  280.     3.5
  281.     Reanswer
  282. .sp 9p
  283. .RT
  284. .sp 2P
  285. .LP
  286.     4
  287.     \fIUnsuccessful set\(hyup\fR 
  288. .sp 1P
  289. .RT
  290. .sp 1P
  291. .LP
  292.     4.1
  293.     SEC
  294. .sp 9p
  295. .RT
  296. .LP
  297.     4.1.1
  298.     SEC received
  299. .LP
  300.     4.1.2
  301.     SEC sent
  302. .sp 1P
  303. .LP
  304.     4.2
  305.     CGC
  306. .sp 9p
  307. .RT
  308. .LP
  309.     4.2.1
  310.     CGCreceived
  311. .LP
  312.     4.2.2
  313.     CGC sent
  314. .sp 1P
  315. .LP
  316.     4.3
  317.     NNC
  318. .sp 9p
  319. .RT
  320. .LP
  321.     4.3.1
  322.     NNC received
  323. .LP
  324.     4.3.2
  325.     NNC sent
  326. .bp
  327. .sp 1P
  328. .LP
  329.     4.4
  330.     ADI
  331. .sp 9p
  332. .RT
  333. .LP
  334. *
  335.     4.4.1
  336.     ADI received
  337. .LP
  338. *
  339.     4.4.2
  340.     ADI sent
  341. .sp 1P
  342. .LP
  343.     4.5
  344.     CFL
  345. .sp 9p
  346. .RT
  347. .LP
  348.     4.5.1
  349.     CFL received
  350. .LP
  351.     4.5.2
  352.     CFL sent
  353. .sp 1P
  354. .LP
  355.     4.6
  356.     SSB
  357. .sp 9p
  358. .RT
  359. .LP
  360. *
  361.     4.6.1
  362.     SSB received
  363. .LP
  364. *
  365.     4.6.2
  366.     SSB sent
  367. .sp 1P
  368. .LP
  369.     4.7
  370.     UNN
  371. .sp 9p
  372. .RT
  373. .LP
  374. *
  375.     4.7.1
  376.     UNN received
  377. .LP
  378. *
  379.     4.7.2
  380.     UNN sent
  381. .sp 1P
  382. .LP
  383.     4.8
  384.     LOS
  385. .sp 9p
  386. .RT
  387. .LP
  388.     4.8.1
  389.     LOS received
  390. .LP
  391.     4.8.2
  392.     LOS sent
  393. .sp 1P
  394. .LP
  395.     4.9
  396.     SST
  397. .sp 9p
  398. .RT
  399. .LP
  400.     4.9.1
  401.     SST received
  402. .LP
  403.     4.9.2
  404.     SST sent
  405. .sp 1P
  406. .LP
  407.     4.10
  408.     ACB
  409. .sp 9p
  410. .RT
  411. .LP
  412.     4.10.1
  413.     ACB received
  414. .LP
  415.     4.10.2
  416.     ACB sent
  417. .sp 1P
  418. .LP
  419.     4.11
  420.     DPN
  421. .sp 9p
  422. .RT
  423. .LP
  424.     4.11.1
  425.     DPN received
  426. .LP
  427.     4.11.2
  428.     DPN sent
  429. .sp 2P
  430. .LP
  431.     5
  432.     \fIAbnormal situation during a call\fR 
  433. .sp 1P
  434. .RT
  435. .sp 1P
  436. .LP
  437.     5.1
  438.     Inability to release in response to a CLF
  439. .sp 9p
  440. .RT
  441. .sp 1P
  442. .LP
  443.     5.2
  444.     Inability to release in response to a backward signal
  445. .sp 9p
  446. .RT
  447. .sp 1P
  448. .LP
  449.     5.3
  450.     Timers
  451. .sp 9p
  452. .RT
  453. .LP
  454.     5.3.1
  455.     T2
  456. .LP
  457.     5.3.2
  458.     T3
  459. .LP
  460.     5.3.3
  461.     T4
  462. .LP
  463.     5.3.4
  464.     T5
  465. .LP
  466.     5.3.5
  467.     T6
  468. .LP
  469. *
  470.     5.3.6
  471.     ANS signal not received (Q.118 Timer)
  472. .LP
  473. *
  474.     5.3.7
  475.     Delay in clearing by calling party (Q.118
  476. Timer)
  477. .sp 1P
  478. .LP
  479.     5.4
  480.     Reset of circuits during a call
  481. .sp 9p
  482. .RT
  483. .LP
  484.     5.4.1
  485.     Of an outgoing circuit
  486. .LP
  487.     5.4.2
  488.     Of an incoming circuit
  489. .bp
  490. .sp 1P
  491. .LP
  492.     5.5
  493.     Receipt of unreasonable signalling information
  494. .sp 9p
  495. .RT
  496. .LP
  497.     5.5.1
  498.     (Now test No. 1.5.1)
  499. .LP
  500. fs
  501.     5.5.2
  502.     Received
  503. .sp 1P
  504. .LP
  505.     5.6
  506.     Interruption of signalling relation
  507. .sp 9p
  508. .RT
  509. .sp 2P
  510. .LP
  511.     6
  512.     \fISpecial call set\(hyup\fR 
  513. .sp 1P
  514. .RT
  515. .sp 1P
  516. .LP
  517.     6.1
  518.     Continuity check call
  519. .sp 9p
  520. .RT
  521. .LP
  522. *
  523.     6.1.1
  524.     COT applied on an outgoing circuit
  525. .LP
  526. *
  527.     6.1.2
  528.     COT applied on previous circuit
  529. .LP
  530. *
  531.     6.1.3
  532.     COT on a satellite circuit
  533. .LP
  534.     6.1.4
  535.     Calling party clears during a COT
  536. .LP
  537. *
  538.     6.1.5
  539.     Delay of through connect
  540. .LP
  541.     6.1.6
  542.     COT unsuccessful
  543. .LP
  544.     6.1.7
  545.     COT received on incoming circuit
  546. .sp 1P
  547. .LP
  548.     6.2
  549.     Automatic repeat attempt
  550. .sp 9p
  551. .RT
  552. .LP
  553.     6.2.1
  554.     Dual seizure
  555. .LP
  556.     6.2.2
  557.     Circuit reset
  558. .LP
  559.     6.2.3
  560.     Reception of unreasonable signal information
  561. .LP
  562. *
  563.     6.2.4
  564.     Blocking of the circuit
  565. .LP
  566.     6.2.5
  567.     Continuity check failure
  568. .sp 1P
  569. .LP
  570.     6.3
  571.     Dual seizure
  572. .sp 9p
  573. .RT
  574. .LP
  575.     6.3.1
  576.     Dual seizure for controlling side
  577. .sp 2P
  578. .LP
  579.     7
  580.     \fISupplementary services\fR 
  581. .sp 1P
  582. .RT
  583. .sp 1P
  584. .LP
  585. fs
  586.     7.1
  587.     CUG
  588. .sp 9p
  589. .RT
  590. .sp 1P
  591. .LP
  592. fs
  593.     7.2
  594.     User access to the calling line identity
  595. .sp 9p
  596. .RT
  597. .sp 1P
  598. .LP
  599. fs
  600.     7.3
  601.     User access to the called line identity
  602. .sp 9p
  603. .RT
  604. .sp 1P
  605. .LP
  606. fs
  607.     7.4
  608.     Redirection of calls
  609. .sp 9p
  610. .RT
  611. .sp 1P
  612. .LP
  613. fs
  614.     7.5
  615.     CCBS
  616. .sp 9p
  617. .RT
  618. .sp 1P
  619. .LP
  620. fs
  621.     7.6
  622.     Network access to calling line identity
  623. .sp 9p
  624. .RT
  625. .sp 2P
  626. .LP
  627.     8
  628.     \fIPerformance tests\fR 
  629. .sp 1P
  630. .RT
  631. .LP
  632.     \fINote\fR \ \(em\ For further study.
  633. .LP
  634. .rs
  635. .sp 10P
  636. .ad r
  637. \fBFigure 1/Q.783, p.\fR 
  638. .sp 1P
  639. .RT
  640. .ad b
  641. .RT
  642. .LP
  643. .bp
  644. .ce
  645. \fBH.T. [T1.783]\fR 
  646. .ce
  647. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  648. .ps 9
  649. .vs 11
  650. .nr VS 11
  651. .nr PS 9
  652. .TS
  653. center box;
  654. lw(228p) .
  655. TEST NUMBER:\ 1.1
  656. _
  657. .T&
  658. lw(228p) .
  659. REFERENCE:
  660. _
  661. .T&
  662. lw(228p) .
  663. TITLE:\ Circuit supervision
  664. _
  665. .T&
  666. lw(228p) .
  667.  {
  668. SUBTITLE:\ Non\(hyallocated circuits
  669.  }
  670. _
  671. .T&
  672. lw(228p) .
  673.  {
  674. PURPOSE:
  675. To verify that on receipt of a CIC relating to a circuit
  676. which does not exist, SP\ A will discard the message and alert
  677. maintenance personnel
  678.  }
  679. _
  680. .T&
  681. lw(228p) .
  682.  {
  683. PRE\(hyTEST CONDITIONS:
  684. Arrange the data in signalling point\ B such that
  685. the CIC identifies a circuit that does not exist between SP\ A and
  686. SP\ B
  687.  }
  688. _
  689. .T&
  690. cw(72p) | cw(84p) | cw(72p) .
  691. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  692. _
  693. .T&
  694. lw(228p) .
  695. EXPECTED MESSAGE SEQUENCE:
  696. .T&
  697. lw(72p) | lw(84p) | lw(72p) .
  698. SP\ \ A        SP\ \ B
  699. .T&
  700. lw(72p) | cw(84p) | lw(72p) .
  701.     <-------------------------    IAM
  702. _
  703. .T&
  704. lw(72p) | cw(84p) | lw(72p) .
  705. TEST DESCRIPTION        
  706. _
  707. .T&
  708. cw(18p) | lw(210p) .
  709. 1.     {
  710. Arrange for SP B to send an initial address message.
  711. Record the message sequence using a signal monitor.
  712.  }
  713. .T&
  714. cw(18p) | lw(210p) .
  715. 2.     {
  716. CHECK A:
  717. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  718.  }
  719. .T&
  720. cw(18p) | lw(210p) .
  721. 3.     {
  722. CHECK B:
  723. WAS THE MESSAGE SEQUENCE AS SHOWN
  724. ABOVE? |  |  |  |  |  |  
  725.  }
  726. .T&
  727. cw(18p) | lw(210p) .
  728. 4.     {
  729. CHECK C:
  730. WAS THE INDICATION GIVEN TO THE MAINTENANCE
  731. PERSONNEL? |  |  |  |  |  | 
  732.  }
  733. _
  734. .TE
  735. .nr PS 9
  736. .RT
  737. .ad r
  738. \fBTableau [T1.783], p.\fR 
  739. .sp 1P
  740. .RT
  741. .ad b
  742. .RT
  743. .LP
  744. .bp
  745. .ce
  746. \fBH.T. [T2.783]\fR 
  747. .ce
  748. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  749. .ps 9
  750. .vs 11
  751. .nr VS 11
  752. .nr PS 9
  753. .TS
  754. center box;
  755. lw(228p) .
  756. TEST NUMBER:\ 1.2.1
  757. _
  758. .T&
  759. lw(228p) .
  760. REFERENCE:\ Q.724 \(sc 1.15.1
  761. _
  762. .T&
  763. lw(228p) .
  764. TITLE:\ Reset of circuits
  765. _
  766. .T&
  767. lw(228p) .
  768.  {
  769. SUBTITLE:\ RSC received on an idle circuit
  770.  }
  771. _
  772. .T&
  773. lw(228p) .
  774.  {
  775. PURPOSE:\ To verify that on receipt of a reset circuit signal SP\ A will
  776. respond by sending a release guard signal
  777.  }
  778. _
  779. .T&
  780. lw(228p) .
  781.  {
  782. PRE\(hyTEST CONDITIONS:\ The circuit is idle
  783.  }
  784. _
  785. .T&
  786. cw(72p) | cw(84p) | cw(72p) .
  787. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  788. _
  789. .T&
  790. lw(228p) .
  791. EXPECTED MESSAGE SEQUENCE:
  792. .T&
  793. lw(72p) | lw(84p) | lw(72p) .
  794. SP\ \ A        SP\ \ B
  795. .T&
  796. lw(72p) | cw(84p) | lw(72p) .
  797.     <-------------------------    RSC
  798. .T&
  799. lw(72p) | cw(84p) | lw(72p) .
  800. RLG    ------------------------->    
  801. _
  802. .T&
  803. lw(72p) | cw(84p) | lw(72p) .
  804. TEST DESCRIPTION        
  805. _
  806. .T&
  807. cw(18p) | lw(210p) .
  808. 1.     {
  809. Arrange for SP B to send a reset\(hycircuit signal.
  810. Record the message sequence using a signal monitor.
  811.  }
  812. .T&
  813. cw(18p) | lw(210p) .
  814. 2.     {
  815. CHECK A:
  816. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  817.  }
  818. .T&
  819. cw(18p) | lw(210p) .
  820. 3.     {
  821. CHECK B:
  822. WAS THE MESSAGE SEQUENCE AS
  823. ABOVE? |  |  |  |  |  | 
  824.  }
  825. _
  826. .TE
  827. .nr PS 9
  828. .RT
  829. .ad r
  830. \fBTableau [T2.783], p.\fR 
  831. .sp 1P
  832. .RT
  833. .ad b
  834. .RT
  835. .LP
  836. .bp
  837. .ce
  838. \fBH.T. [T3.783]\fR 
  839. .ce
  840. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  841. .ps 9
  842. .vs 11
  843. .nr VS 11
  844. .nr PS 9
  845. .TS
  846. center box;
  847. lw(228p) .
  848. TEST NUMBER:\ 1.2.2
  849. _
  850. .T&
  851. lw(228p) .
  852. REFERENCE:\ Q.724 \(sc 1.15.1
  853. _
  854. .T&
  855. lw(228p) .
  856. TITLE:\ Reset of circuits
  857. _
  858. .T&
  859. lw(228p) .
  860.  {
  861. SUBTITLE:\ RSC sent on an idle circuit
  862.  }
  863. _
  864. .T&
  865. lw(228p) .
  866.  {
  867. PURPOSE:\ To verify that SP A is able to generate reset\(hycircuit
  868. signal
  869.  }
  870. _
  871. .T&
  872. lw(228p) .
  873.  {
  874. PRE\(hyTEST CONDITIONS:\ The circuit is idle
  875.  }
  876. _
  877. .T&
  878. cw(72p) | cw(84p) | cw(72p) .
  879. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  880. _
  881. .T&
  882. lw(228p) .
  883. EXPECTED MESSAGE SEQUENCE:
  884. .T&
  885. lw(72p) | lw(84p) | lw(72p) .
  886. SP\ \ A        SP\ \ B
  887. .T&
  888. lw(72p) | cw(84p) | lw(72p) .
  889. RSC    ------------------------->    
  890. .T&
  891. lw(72p) | cw(84p) | lw(72p) .
  892.     <-------------------------    RLG
  893. _
  894. .T&
  895. lw(72p) | cw(84p) | lw(72p) .
  896. TEST DESCRIPTION        
  897. _
  898. .T&
  899. cw(18p) | lw(210p) .
  900. 1.     {
  901. Arrange for SP A to send a reset\(hycircuit signal.
  902. Record the message sequence using a signal monitor.
  903.  }
  904. .T&
  905. cw(18p) | lw(210p) .
  906. 2.     {
  907. CHECK A:
  908. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  909.  }
  910. .T&
  911. cw(18p) | lw(210p) .
  912. 3.     {
  913. CHECK B:
  914. WAS THE MESSAGE SEQUENCE AS
  915. ABOVE? |  |  |  |  |  | 
  916.  }
  917. _
  918. .TE
  919. .nr PS 9
  920. .RT
  921. .ad r
  922. \fBTableau [T3.783], p.\fR 
  923. .sp 1P
  924. .RT
  925. .ad b
  926. .RT
  927. .LP
  928. .bp
  929. .ce
  930. \fBH.T. [T4.783]\fR 
  931. .ce
  932. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  933. .ps 9
  934. .vs 11
  935. .nr VS 11
  936. .nr PS 9
  937. .TS
  938. center box;
  939. lw(228p) .
  940. TEST NUMBER:\ 1.2.3
  941. _
  942. .T&
  943. lw(228p) .
  944. REFERENCE:\ Q.724 \(sc 1.15.2
  945. _
  946. .T&
  947. lw(228p) .
  948. TITLE:\ Reset of circuits
  949. _
  950. .T&
  951. lw(228p) .
  952.  {
  953. SUBTITLE:\ Group reset received
  954.  }
  955. _
  956. .T&
  957. lw(228p) .
  958.  {
  959. PURPOSE:
  960. To verify that on receipt of two circuit group reset messages
  961. within a period of 5\ seconds, SP\ A will respond by sending a circuit
  962. reset acknowledge message
  963.  }
  964. _
  965. .T&
  966. lw(228p) .
  967. PRE\(hyTEST CONDITIONS:
  968. _
  969. .T&
  970. cw(72p) | cw(84p) | cw(72p) .
  971. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  972. _
  973. .T&
  974. lw(228p) .
  975. EXPECTED MESSAGE SEQUENCE:
  976. .T&
  977. lw(72p) | lw(84p) | lw(72p) .
  978. SP\ \ A        SP\ \ B
  979. .T&
  980. lw(72p) | cw(84p) | lw(72p) .
  981.     <-------------------------    GRS
  982. .T&
  983. lw(72p) | cw(84p) | lw(72p) .
  984.     <-------------------------    GRS
  985. .T&
  986. lw(72p) | cw(84p) | lw(72p) .
  987. GRA    ------------------------->    
  988. _
  989. .T&
  990. lw(72p) | cw(84p) | lw(72p) .
  991. TEST DESCRIPTION        
  992. _
  993. .T&
  994. cw(18p) | lw(210p) .
  995. 1.     {
  996. Arrange for SP B to send two circuit group reset messages within a period
  997. of 5\ seconds.
  998. Record the message sequence using a signal monitor.
  999.  }
  1000. .T&
  1001. cw(18p) | lw(210p) .
  1002. 2.     {
  1003. CHECK A:
  1004. IS THE CIRCUIT GROUP IDLE? |  |  |  |  |  | 
  1005.  }
  1006. .T&
  1007. cw(18p) | lw(210p) .
  1008. 3.     {
  1009. CHECK B:
  1010. WAS THE MESSAGE SEQUENCE AS
  1011. ABOVE? |  |  |  |  |  | 
  1012.  }
  1013. _
  1014. .TE
  1015. .nr PS 9
  1016. .RT
  1017. .ad r
  1018. \fBTableau [T4.783], p.\fR 
  1019. .sp 1P
  1020. .RT
  1021. .ad b
  1022. .RT
  1023. .LP
  1024. .bp
  1025. .ce
  1026. \fBH.T. [T5.783]\fR 
  1027. .ce
  1028. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1029. .ps 9
  1030. .vs 11
  1031. .nr VS 11
  1032. .nr PS 9
  1033. .TS
  1034. center box;
  1035. lw(228p) .
  1036. TEST NUMBER:\ 1.2.4
  1037. _
  1038. .T&
  1039. lw(228p) .
  1040. REFERENCE:\ Q.724 \(sc 1.15.2
  1041. _
  1042. .T&
  1043. lw(228p) .
  1044. TITLE:\ Reset of circuits
  1045. _
  1046. .T&
  1047. lw(228p) .
  1048. SUBTITLE:\ Group reset sent
  1049. _
  1050. .T&
  1051. lw(228p) .
  1052.  {
  1053. PURPOSE:\ To verify that SP A is able to generate a circuit group reset
  1054. message
  1055.  }
  1056. _
  1057. .T&
  1058. lw(228p) .
  1059. PRE\(hyTEST CONDITIONS:
  1060. _
  1061. .T&
  1062. cw(72p) | cw(84p) | cw(72p) .
  1063. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  1064. _
  1065. .T&
  1066. lw(228p) .
  1067. EXPECTED MESSAGE SEQUENCE:
  1068. .T&
  1069. lw(72p) | lw(84p) | lw(72p) .
  1070. SP\ \ A        SP\ \ B
  1071. .T&
  1072. lw(72p) | cw(84p) | lw(72p) .
  1073. GRS    ------------------------->    
  1074. .T&
  1075. lw(72p) | cw(84p) | lw(72p) .
  1076. GRS    ------------------------->    
  1077. .T&
  1078. lw(72p) | cw(84p) | lw(72p) .
  1079.     <-------------------------    GRA
  1080. _
  1081. .T&
  1082. lw(72p) | cw(84p) | lw(72p) .
  1083. TEST DESCRIPTION        
  1084. _
  1085. .T&
  1086. cw(18p) | lw(210p) .
  1087. 1.     {
  1088. Arrange for SP A to send two circuit group reset messages within a period
  1089. of 5\ seconds.
  1090. Record the message sequence using a signal monitor.
  1091.  }
  1092. .T&
  1093. cw(18p) | lw(210p) .
  1094. 2.     {
  1095. CHECK A:
  1096. IS THE CIRCUIT GROUP IDLE? |  |  |  |  |  | 
  1097.  }
  1098. .T&
  1099. cw(18p) | lw(210p) .
  1100. 3.     {
  1101. CHECK B:
  1102. WAS THE MESSAGE SEQUENCE AS
  1103. ABOVE? |  |  |  |  |  | 
  1104.  }
  1105. _
  1106. .TE
  1107. .nr PS 9
  1108. .RT
  1109. .ad r
  1110. \fBTableau [T5.783], p.\fR 
  1111. .sp 1P
  1112. .RT
  1113. .ad b
  1114. .RT
  1115. .LP
  1116. .bp
  1117. .ce
  1118. \fBH.T. [T6.783]\fR 
  1119. .ce
  1120. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1121. .ps 9
  1122. .vs 11
  1123. .nr VS 11
  1124. .nr PS 9
  1125. .TS
  1126. center box;
  1127. lw(228p) .
  1128. TEST NUMBER:\ 1.3.1.1
  1129. _
  1130. .T&
  1131. lw(228p) .
  1132. REFERENCE:\ Q.724 \(sc 5.2
  1133. _
  1134. .T&
  1135. lw(228p) .
  1136.  {
  1137. TITLE:\ Group blocking/unblocking
  1138.  }
  1139. _
  1140. .T&
  1141. lw(228p) .
  1142. SUBTITLE:\ HGB received
  1143. _
  1144. .T&
  1145. lw(228p) .
  1146.  {
  1147. PURPOSE:\ To verify that the hardware failure group blocking procedure can
  1148. be correctly initiated
  1149.  }
  1150. _
  1151. .T&
  1152. lw(228p) .
  1153. PRE\(hyTEST CONDITIONS:
  1154. _
  1155. .T&
  1156. cw(72p) | cw(84p) | cw(72p) .
  1157. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  1158. _
  1159. .T&
  1160. lw(228p) .
  1161. EXPECTED MESSAGE SEQUENCE:
  1162. .T&
  1163. lw(72p) | lw(84p) | lw(72p) .
  1164. SP\ \ A        SP\ \ B
  1165. .T&
  1166. lw(72p) | cw(84p) | lw(72p) .
  1167.     <-------------------------    HGB
  1168. .T&
  1169. lw(72p) | cw(84p) | lw(72p) .
  1170.     <-------------------------    HGB
  1171. .T&
  1172. lw(72p) | cw(84p) | lw(72p) .
  1173. HBA    ------------------------->    
  1174. .T&
  1175. lw(72p) | cw(84p) | lw(72p) .
  1176.     <-------------------------    HGU
  1177. .T&
  1178. lw(72p) | cw(84p) | lw(72p) .
  1179.     <-------------------------    HGU
  1180. .T&
  1181. lw(72p) | cw(84p) | lw(72p) .
  1182. HUA    ------------------------->    
  1183. _
  1184. .T&
  1185. lw(72p) | cw(84p) | lw(72p) .
  1186. TEST DESCRIPTION        
  1187. _
  1188. .T&
  1189. cw(18p) | lw(210p) .
  1190. 1.     {
  1191. Arrange for SP B to send two hardware failure oriented group blocking
  1192. messages within a period of 5\ seconds.
  1193. Record the message sequence using a signal monitor.
  1194.  }
  1195. .T&
  1196. cw(18p) | lw(210p) .
  1197. 2.     {
  1198. CHECK A:
  1199. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ B ON THE
  1200. CIRCUITS INDICATED BY THE RANGE FIELD IN THE HGB
  1201. MESSAGE 
  1202.  }
  1203. .T&
  1204. cw(18p) | lw(210p) .
  1205. 3.     {
  1206. Arrange for SP B to send two hardware failure oriented group unblocking
  1207. messages within a period of 5 seconds.
  1208.  }
  1209. .T&
  1210. cw(18p) | lw(210p) .
  1211. 4.     {
  1212. CHECK B:
  1213. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER SP ON THE
  1214. CIRCUITS INDICATED BY THE RANGE FIELD
  1215.  }
  1216. .T&
  1217. cw(18p) | lw(210p) .
  1218. 5.     {
  1219. CHECK C:
  1220. WAS THE MESSAGE SEQUENCE AS
  1221. ABOVE? |  |  |  |  |  | 
  1222.  }
  1223. _
  1224. .TE
  1225. .nr PS 9
  1226. .RT
  1227. .ad r
  1228. \fBTableau [T6.783], p.\fR 
  1229. .sp 1P
  1230. .RT
  1231. .ad b
  1232. .RT
  1233. .LP
  1234. .bp
  1235. .ce
  1236. \fBH.T. [T7.783]\fR 
  1237. .ce
  1238. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1239. .ps 9
  1240. .vs 11
  1241. .nr VS 11
  1242. .nr PS 9
  1243. .TS
  1244. center box;
  1245. lw(228p) .
  1246. TEST NUMBER:\ 1.3.1.2
  1247. _
  1248. .T&
  1249. lw(228p) .
  1250. REFERENCE:\ Q.724 \(sc 5.2
  1251. _
  1252. .T&
  1253. lw(228p) .
  1254.  {
  1255. TITLE:\ Group blocking/unblocking
  1256.  }
  1257. _
  1258. .T&
  1259. lw(228p) .
  1260. SUBTITLE:\ HGB sent
  1261. _
  1262. .T&
  1263. lw(228p) .
  1264.  {
  1265. PURPOSE:
  1266. To verify that SP A is able to generate both hardware failure
  1267. oriented group blocking messages and hardware failure oriented group
  1268. unblocking messages
  1269.  }
  1270. _
  1271. .T&
  1272. lw(228p) .
  1273. PRE\(hyTEST CONDITIONS:
  1274. _
  1275. .T&
  1276. cw(72p) | cw(84p) | cw(72p) .
  1277. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  1278. _
  1279. .T&
  1280. lw(228p) .
  1281. EXPECTED MESSAGE SEQUENCE:
  1282. .T&
  1283. lw(72p) | lw(84p) | lw(72p) .
  1284. SP\ \ A        SP\ \ B
  1285. .T&
  1286. lw(72p) | cw(84p) | lw(72p) .
  1287. HGB    ------------------------->    
  1288. .T&
  1289. lw(72p) | cw(84p) | lw(72p) .
  1290. HGB    ------------------------->    
  1291. .T&
  1292. lw(72p) | cw(84p) | lw(72p) .
  1293.     <-------------------------    HGB
  1294. .T&
  1295. lw(72p) | cw(84p) | lw(72p) .
  1296. HGU    ------------------------->    
  1297. .T&
  1298. lw(72p) | cw(84p) | lw(72p) .
  1299. HGU    ------------------------->    
  1300. .T&
  1301. lw(72p) | cw(84p) | lw(72p) .
  1302.     <-------------------------    HUA
  1303. _
  1304. .T&
  1305. lw(72p) | cw(84p) | lw(72p) .
  1306. TEST DESCRIPTION        
  1307. _
  1308. .T&
  1309. cw(18p) | lw(210p) .
  1310. 1.     {
  1311. Arrange for SP A to send two hardware failure oriented group blocking
  1312. messages within a period of 5\ seconds.
  1313. Record the message sequence using a signal monitor.
  1314.  }
  1315. .T&
  1316. cw(18p) | lw(210p) .
  1317. 2.     {
  1318. CHECK A:
  1319. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ A ON THE
  1320. CIRCUITS INDICATED BY THE RANGE FIELD IN THE HGB
  1321. MESSAGE
  1322.  }
  1323. .T&
  1324. cw(18p) | lw(210p) .
  1325. 3.     {
  1326. Arrange for SP A to send two hardware failure oriented group unblocking
  1327. messages within a period of 5 seconds.
  1328.  }
  1329. .T&
  1330. cw(18p) | lw(210p) .
  1331. 4.     {
  1332. CHECK B:
  1333. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER SP ON THE
  1334. CIRCUIT INDICATED BY THE RANGE FIELD
  1335.  }
  1336. .T&
  1337. cw(18p) | lw(210p) .
  1338. 5.     {
  1339. CHECK C:
  1340. WAS THE MESSAGE SEQUENCE AS
  1341. ABOVE? |  |  |  |  |  | 
  1342.  }
  1343. _
  1344. .TE
  1345. .nr PS 9
  1346. .RT
  1347. .ad r
  1348. \fBTableau [T7.783], p.\fR 
  1349. .sp 1P
  1350. .RT
  1351. .ad b
  1352. .RT
  1353. .LP
  1354. .bp
  1355. .ce
  1356. \fBH.T. [T8.783]\fR 
  1357. .ce
  1358. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1359. .ps 9
  1360. .vs 11
  1361. .nr VS 11
  1362. .nr PS 9
  1363. .TS
  1364. center box;
  1365. lw(228p) .
  1366. TEST NUMBER:\ 1.3.1.3
  1367. _
  1368. .T&
  1369. lw(228p) .
  1370. REFERENCE:\ Q.724 \(sc 5.1
  1371. _
  1372. .T&
  1373. lw(228p) .
  1374.  {
  1375. TITLE:\ Group blocking/unblocking
  1376.  }
  1377. _
  1378. .T&
  1379. lw(228p) .
  1380. SUBTITLE:\ MGB received
  1381. _
  1382. .T&
  1383. lw(228p) .
  1384.  {
  1385. PURPOSE:\ To verify that the maintenance oriented group blocking procedure
  1386. can be correctly initiated
  1387.  }
  1388. _
  1389. .T&
  1390. lw(228p) .
  1391. PRE\(hyTEST CONDITIONS:
  1392. _
  1393. .T&
  1394. cw(72p) | cw(84p) | cw(72p) .
  1395. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  1396. _
  1397. .T&
  1398. lw(228p) .
  1399. EXPECTED MESSAGE SEQUENCE:
  1400. .T&
  1401. lw(72p) | lw(84p) | lw(72p) .
  1402. SP\ \ A        SP\ \ B
  1403. .T&
  1404. lw(72p) | cw(84p) | lw(72p) .
  1405.     <-------------------------    MGB
  1406. .T&
  1407. lw(72p) | cw(84p) | lw(72p) .
  1408.     <-------------------------    MGB
  1409. .T&
  1410. lw(72p) | cw(84p) | lw(72p) .
  1411. MBA    ------------------------->    
  1412. .T&
  1413. lw(72p) | cw(84p) | lw(72p) .
  1414.     <-------------------------    MGU
  1415. .T&
  1416. lw(72p) | cw(84p) | lw(72p) .
  1417.     <-------------------------    MGU
  1418. .T&
  1419. lw(72p) | cw(84p) | lw(72p) .
  1420. MUA    ------------------------->    
  1421. _
  1422. .T&
  1423. lw(72p) | cw(84p) | lw(72p) .
  1424. TEST DESCRIPTION        
  1425. _
  1426. .T&
  1427. cw(18p) | lw(210p) .
  1428. 1.     {
  1429. Arrange for SP B to send two maintenance oriented group blocking messages
  1430. within a period of 5\ seconds.
  1431. Record the message sequence using a signal monitor.
  1432.  }
  1433. .T&
  1434. cw(18p) | lw(210p) .
  1435. 2.     {
  1436. CHECK A:
  1437. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ B ON THE
  1438. CIRCUITS INDICATED BY THE RANGE FIELD IN THE MGB
  1439. MESSAGE
  1440.  }
  1441. .T&
  1442. cw(18p) | lw(210p) .
  1443. 3.     {
  1444. Arrange for SP B to send two maintenance oriented group unblocking
  1445. messages within a period of 5\ seconds.
  1446.  }
  1447. .T&
  1448. cw(18p) | lw(210p) .
  1449. 4.     {
  1450. CHECK B:
  1451. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER SP ON THE
  1452. CIRCUITS INDICATED BY THE RANGE FIELD
  1453.  }
  1454. .T&
  1455. cw(18p) | lw(210p) .
  1456. 5.     {
  1457. CHECK C:
  1458. WAS THE MESSAGE SEQUENCE AS
  1459. ABOVE? |  |  |  |  |  | 
  1460.  }
  1461. _
  1462. .TE
  1463. .nr PS 9
  1464. .RT
  1465. .ad r
  1466. \fBTableau [T8.783], p.\fR 
  1467. .sp 1P
  1468. .RT
  1469. .ad b
  1470. .RT
  1471. .LP
  1472. .bp
  1473. .ce
  1474. \fBH.T. [T9.783]\fR 
  1475. .ce
  1476. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1477. .ps 9
  1478. .vs 11
  1479. .nr VS 11
  1480. .nr PS 9
  1481. .TS
  1482. center box;
  1483. lw(228p) .
  1484. TEST NUMBER:\ 1.3.1.4
  1485. _
  1486. .T&
  1487. lw(228p) .
  1488. REFERENCE:\ Q.724 \(sc 5.1
  1489. _
  1490. .T&
  1491. lw(228p) .
  1492.  {
  1493. TITLE:\ Group blocking/unblocking
  1494.  }
  1495. _
  1496. .T&
  1497. lw(228p) .
  1498. SUBTITLE:\ MGB sent
  1499. _
  1500. .T&
  1501. lw(228p) .
  1502.  {
  1503. PURPOSE:
  1504. To verify that SP A is able to generate both maintenance
  1505. oriented group blocking messages and maintenance oriented group
  1506. unblocking messages
  1507.  }
  1508. _
  1509. .T&
  1510. lw(228p) .
  1511. PRE\(hyTEST CONDITIONS:
  1512. _
  1513. .T&
  1514. cw(72p) | cw(84p) | cw(72p) .
  1515. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  1516. _
  1517. .T&
  1518. lw(228p) .
  1519. EXPECTED MESSAGE SEQUENCE:
  1520. .T&
  1521. lw(72p) | lw(84p) | lw(72p) .
  1522. SP\ \ A        SP\ \ B
  1523. .T&
  1524. lw(72p) | cw(84p) | lw(72p) .
  1525. MGB    ------------------------->    
  1526. .T&
  1527. lw(72p) | cw(84p) | lw(72p) .
  1528. MGB    ------------------------->    
  1529. .T&
  1530. lw(72p) | cw(84p) | lw(72p) .
  1531.     <-------------------------    MGA
  1532. .T&
  1533. lw(72p) | cw(84p) | lw(72p) .
  1534. MGU    ------------------------->    
  1535. .T&
  1536. lw(72p) | cw(84p) | lw(72p) .
  1537. MGU    ------------------------->    
  1538. .T&
  1539. lw(72p) | cw(84p) | lw(72p) .
  1540.     <-------------------------    MUA
  1541. _
  1542. .T&
  1543. lw(72p) | cw(84p) | lw(72p) .
  1544. TEST DESCRIPTION        
  1545. _
  1546. .T&
  1547. cw(18p) | lw(210p) .
  1548. 1.     {
  1549. Arrange for SP A to send two maintenance oriented group blocking messages
  1550. within a period of 5\ seconds.
  1551. Record the message sequence using a signal monitor.
  1552.  }
  1553. .T&
  1554. cw(18p) | lw(210p) .
  1555. 2.     {
  1556. CHECK A:
  1557. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ A ON THE
  1558. CIRCUITS INDICATED BY THE RANGE FIELD IN THE MGB
  1559. MESSAGE
  1560.  }
  1561. .T&
  1562. cw(18p) | lw(210p) .
  1563. 3.     {
  1564. Arrange for SP A to send two maintenance oriented group unblocking
  1565. messages within a period of 5\ seconds.
  1566.  }
  1567. .T&
  1568. cw(18p) | lw(210p) .
  1569. 4.     {
  1570. CHECK B:
  1571. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER SP ON THE
  1572. CIRCUIT INDICATED BY THE RANGE FIELD
  1573.  }
  1574. .T&
  1575. cw(18p) | lw(210p) .
  1576. 5.     {
  1577. CHECK C:
  1578. WAS THE MESSAGE SEQUENCE AS
  1579. ABOVE? |  |  |  |  |  | 
  1580.  }
  1581. _
  1582. .TE
  1583. .nr PS 9
  1584. .RT
  1585. .ad r
  1586. \fBTableau [T9.783], p.\fR 
  1587. .sp 1P
  1588. .RT
  1589. .ad b
  1590. .RT
  1591. .LP
  1592. .bp
  1593. .ce
  1594. \fBH.T. [T10.783]\fR 
  1595. .ce
  1596. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1597. .ps 9
  1598. .vs 11
  1599. .nr VS 11
  1600. .nr PS 9
  1601. .TS
  1602. center box;
  1603. lw(228p) .
  1604. TEST NUMBER:\ 1.3.2.1
  1605. _
  1606. .T&
  1607. lw(228p) .
  1608. REFERENCE:\ Q.724 \(sc 5.1
  1609. _
  1610. .T&
  1611. lw(228p) .
  1612.  {
  1613. TITLE:\ Circuit blocking/unblocking
  1614.  }
  1615. _
  1616. .T&
  1617. lw(228p) .
  1618. SUBTITLE:\ BLO received
  1619. _
  1620. .T&
  1621. lw(228p) .
  1622.  {
  1623. PURPOSE:\ To verify that the blocking/unblocking procedure can be
  1624. correctly initiated
  1625.  }
  1626. _
  1627. .T&
  1628. lw(228p) .
  1629. PRE\(hyTEST CONDITIONS:
  1630. _
  1631. .T&
  1632. cw(72p) | cw(84p) | cw(72p) .
  1633. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  1634. _
  1635. .T&
  1636. lw(228p) .
  1637. EXPECTED MESSAGE SEQUENCE:
  1638. .T&
  1639. lw(72p) | lw(84p) | lw(72p) .
  1640. SP\ \ A        SP\ \ B
  1641. .T&
  1642. lw(72p) | cw(84p) | lw(72p) .
  1643.     <-------------------------    BLO
  1644. .T&
  1645. lw(72p) | cw(84p) | lw(72p) .
  1646. BLA    ------------------------->    
  1647. .T&
  1648. lw(72p) | cw(84p) | lw(72p) .
  1649.     <-------------------------    UBL
  1650. .T&
  1651. lw(72p) | cw(84p) | lw(72p) .
  1652. UBA    ------------------------->    
  1653. _
  1654. .T&
  1655. lw(72p) | cw(84p) | lw(72p) .
  1656. TEST DESCRIPTION        
  1657. _
  1658. .T&
  1659. cw(18p) | lw(210p) .
  1660. 1.     {
  1661. Arrange for SP B to send a blocking signal.
  1662. Record the message sequence using a signal monitor.
  1663.  }
  1664. .T&
  1665. cw(18p) | lw(210p) .
  1666. 2.     {
  1667. CHECK A:
  1668. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ B ON THIS
  1669. CIRCUIT
  1670.  }
  1671. .T&
  1672. cw(18p) | lw(210p) .
  1673. 3.     {
  1674. Arrange for SP B to send an unblocking signal.
  1675.  }
  1676. .T&
  1677. cw(18p) | lw(210p) .
  1678. 4.     {
  1679. CHECK B:
  1680. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER EXCHANGE ON
  1681. THIS CIRCUIT
  1682.  }
  1683. .T&
  1684. cw(18p) | lw(210p) .
  1685. 5.     {
  1686. CHECK C:
  1687. WAS THE MESSAGE SEQUENCE AS
  1688. ABOVE? |  |  |  |  |  | 
  1689.  }
  1690. _
  1691. .TE
  1692. .nr PS 9
  1693. .RT
  1694. .ad r
  1695. \fBTableau [T10.783], p.\fR 
  1696. .sp 1P
  1697. .RT
  1698. .ad b
  1699. .RT
  1700. .LP
  1701. .bp
  1702. .ce
  1703. \fBH.T. [T11.783]\fR 
  1704. .ce
  1705. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1706. .ps 9
  1707. .vs 11
  1708. .nr VS 11
  1709. .nr PS 9
  1710. .TS
  1711. center box;
  1712. lw(228p) .
  1713. TEST NUMBER:\ 1.3.2.2
  1714. _
  1715. .T&
  1716. lw(228p) .
  1717. REFERENCE:\ Q.724 \(sc 5.1
  1718. _
  1719. .T&
  1720. lw(228p) .
  1721.  {
  1722. TITLE:\ Circuit blocking/unblocking
  1723.  }
  1724. _
  1725. .T&
  1726. lw(228p) .
  1727. SUBTITLE:\ BLO sent
  1728. _
  1729. .T&
  1730. lw(228p) .
  1731.  {
  1732. PURPOSE:\ To verify that SP A is able to generate blocking
  1733. messages
  1734.  }
  1735. _
  1736. .T&
  1737. lw(228p) .
  1738. PRE\(hyTEST CONDITIONS:
  1739. _
  1740. .T&
  1741. cw(72p) | cw(84p) | cw(72p) .
  1742. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  1743. _
  1744. .T&
  1745. lw(228p) .
  1746. EXPECTED MESSAGE SEQUENCE:
  1747. .T&
  1748. lw(72p) | lw(84p) | lw(72p) .
  1749. SP\ \ A        SP\ \ B
  1750. .T&
  1751. lw(72p) | cw(84p) | lw(72p) .
  1752. BLO    ------------------------->    
  1753. .T&
  1754. lw(72p) | cw(84p) | lw(72p) .
  1755.     <-------------------------    BLA
  1756. .T&
  1757. lw(72p) | cw(84p) | lw(72p) .
  1758. UBL    ------------------------->    
  1759. .T&
  1760. lw(72p) | cw(84p) | lw(72p) .
  1761.     <-------------------------    UBA
  1762. _
  1763. .T&
  1764. lw(72p) | cw(84p) | lw(72p) .
  1765. TEST DESCRIPTION        
  1766. _
  1767. .T&
  1768. cw(18p) | lw(210p) .
  1769. 1.     {
  1770. Arrange for SP A to send a blocking signal.
  1771. Record the message sequence using a signal monitor.
  1772.  }
  1773. .T&
  1774. cw(18p) | lw(210p) .
  1775. 2.     {
  1776. CHECK A:
  1777. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ A ON THIS
  1778. CIRCUIT
  1779.  }
  1780. .T&
  1781. cw(18p) | lw(210p) .
  1782. 3.     {
  1783. Arrange for SP A to send an unblocking signal.
  1784.  }
  1785. .T&
  1786. cw(18p) | lw(210p) .
  1787. 4.     {
  1788. CHECK B:
  1789. VERIFY THAT A CALL CAN BE ORIGINATED FROM EITHER SP ON THIS
  1790. CIRCUIT
  1791.  }
  1792. .T&
  1793. cw(18p) | lw(210p) .
  1794. 5.     {
  1795. CHECK C:
  1796. WAS THE MESSAGE SEQUENCE AS SHOWN
  1797. ABOVE? |  |  |  |  |  | 
  1798.  }
  1799. _
  1800. .TE
  1801. .nr PS 9
  1802. .RT
  1803. .ad r
  1804. \fBTableau [T11.783], p.\fR 
  1805. .sp 1P
  1806. .RT
  1807. .ad b
  1808. .RT
  1809. .LP
  1810. .bp
  1811. .ce
  1812. \fBH.T. [T12.783]\fR 
  1813. .ce
  1814. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1815. .ps 9
  1816. .vs 11
  1817. .nr VS 11
  1818. .nr PS 9
  1819. .TS
  1820. center box;
  1821. lw(228p) .
  1822. TEST NUMBER:\ 1.3.2.3
  1823. _
  1824. .T&
  1825. lw(228p) .
  1826. REFERENCE:\ Q.724 \(sc 5.1
  1827. _
  1828. .T&
  1829. lw(228p) .
  1830.  {
  1831. TITLE:\ Circuit blocking/unblocking
  1832.  }
  1833. _
  1834. .T&
  1835. lw(228p) .
  1836.  {
  1837. SUBTITLE:\ Blocking from both ends: removal of blocking from
  1838. one end
  1839.  }
  1840. _
  1841. .T&
  1842. lw(228p) .
  1843.  {
  1844. PURPOSE:\ To verify that the blocking/unblocking procedure can be correctly
  1845. initiated
  1846.  }
  1847. _
  1848. .T&
  1849. lw(228p) .
  1850. PRE\(hyTEST CONDITIONS:
  1851. _
  1852. .T&
  1853. cw(72p) | cw(84p) | cw(72p) .
  1854. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  1855. _
  1856. .T&
  1857. lw(228p) .
  1858. EXPECTED MESSAGE SEQUENCE:
  1859. .T&
  1860. lw(72p) | lw(84p) | lw(72p) .
  1861. SP\ \ A        SP\ \ B
  1862. .T&
  1863. lw(72p) | cw(84p) | lw(72p) .
  1864. BLO    ------------------------->    
  1865. .T&
  1866. lw(72p) | cw(84p) | lw(72p) .
  1867.     <-------------------------    BLA
  1868. .T&
  1869. lw(72p) | cw(84p) | lw(72p) .
  1870.     <-------------------------    BLO
  1871. .T&
  1872. lw(72p) | cw(84p) | lw(72p) .
  1873. BLA    ------------------------->    
  1874. .T&
  1875. lw(72p) | cw(84p) | lw(72p) .
  1876. UBL    ------------------------->    
  1877. .T&
  1878. lw(72p) | cw(84p) | lw(72p) .
  1879.     <-------------------------    UBA
  1880. .T&
  1881. lw(72p) | cw(84p) | lw(72p) .
  1882.     <-------------------------    UBL
  1883. .T&
  1884. lw(72p) | cw(84p) | lw(72p) .
  1885. UBA    ------------------------->    
  1886. _
  1887. .T&
  1888. lw(72p) | cw(84p) | lw(72p) .
  1889. TEST DESCRIPTION        
  1890. _
  1891. .T&
  1892. cw(18p) | lw(210p) .
  1893. 1.     {
  1894. Arrange for SP A to send a blocking signal.
  1895. Record the message sequence using a signal monitor.
  1896.  }
  1897. .T&
  1898. cw(18p) | lw(210p) .
  1899. 2.     {
  1900. CHECK A:
  1901. VERIFY THAT A CALL CAN ONLY BE ORIGINATED FROM SP\ A ON THIS
  1902. CIRCUIT
  1903.  }
  1904. .T&
  1905. cw(18p) | lw(210p) .
  1906. 3.     {
  1907. Arrange for SP B to send a blocking signal.
  1908.  }
  1909. .T&
  1910. cw(18p) | lw(210p) .
  1911. 4.     {
  1912. CHECK B:
  1913. VERIFY THAT A CALL CANNOT BE ORIGINATED ON THIS CIRCUIT BY
  1914. EITHER SP
  1915.  }
  1916. .T&
  1917. cw(18p) | lw(210p) .
  1918. 5.     {
  1919. Arrange for SP A to send an unblocking signal.
  1920.  }
  1921. .T&
  1922. cw(18p) | lw(210p) .
  1923. 6.     {
  1924. CHECK C:
  1925. VERIFY THAT A CALL CAN ONLY BE ORIGINATED BY SP B 
  1926.  }
  1927. .T&
  1928. cw(18p) | lw(210p) .
  1929. 7.     {
  1930. Arrange for SP B to send an unblocking signal.
  1931.  }
  1932. .T&
  1933. cw(18p) | lw(210p) .
  1934. 8.     {
  1935. CHECK D:
  1936. WAS THE MESSAGE SEQUENCE AS
  1937. ABOVE? |  |  |  |  |  | 
  1938.  }
  1939. _
  1940. .TE
  1941. .nr PS 9
  1942. .RT
  1943. .ad r
  1944. \fBTableau [T12.783], p.\fR 
  1945. .sp 1P
  1946. .RT
  1947. .ad b
  1948. .RT
  1949. .LP
  1950. .bp
  1951. .ce
  1952. \fBH.T. [T13.783]\fR 
  1953. .ce
  1954. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  1955. .ps 9
  1956. .vs 11
  1957. .nr VS 11
  1958. .nr PS 9
  1959. .TS
  1960. center box;
  1961. lw(228p) .
  1962. TEST NUMBER:\ 1.3.2.4
  1963. _
  1964. .T&
  1965. lw(228p) .
  1966. REFERENCE:\ Q.724 \(sc 9.2
  1967. _
  1968. .T&
  1969. lw(228p) .
  1970.  {
  1971. TITLE:\ Circuit blocking/unblocking
  1972.  }
  1973. _
  1974. .T&
  1975. lw(228p) .
  1976.  {
  1977. SUBTITLE:\ Interruption from FDM circuits
  1978.  }
  1979. _
  1980. .T&
  1981. lw(228p) .
  1982.  {
  1983. PURPOSE:\ To verify th
  1984. at an interruption of the pilot in FDM
  1985. system causes a blocking signal to be sent 
  1986.  }
  1987. _
  1988. .T&
  1989. lw(228p) .
  1990.  {
  1991. PRE\(hyTEST CONDITIONS:\ The signa
  1992. lling points must be linked by a
  1993. transmission system using FDM 
  1994.  }
  1995. _
  1996. .T&
  1997. cw(72p) | cw(84p) | cw(72p) .
  1998. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  1999. _
  2000. .T&
  2001. lw(228p) .
  2002. EXPECTED MESSAGE SEQUENCE:
  2003. .T&
  2004. lw(72p) | lw(84p) | lw(72p) .
  2005. SP\ \ A        SP\ \ B
  2006. .T&
  2007. lw(72p) | cw(84p) | lw(72p) .
  2008. BLO    ------------------------->    
  2009. .T&
  2010. lw(72p) | cw(84p) | lw(72p) .
  2011.     <-------------------------    BLA
  2012. .T&
  2013. lw(72p) | cw(84p) | lw(72p) .
  2014. UBL    ------------------------->    
  2015. .T&
  2016. lw(72p) | cw(84p) | lw(72p) .
  2017.     <-------------------------    UBA
  2018. _
  2019. .T&
  2020. lw(72p) | cw(84p) | lw(72p) .
  2021. TEST DESCRIPTION        
  2022. _
  2023. .T&
  2024. cw(18p) | lw(210p) .
  2025. 1.     {
  2026. Arrange for the reception of the pilot signal at SP A to be interrupted
  2027. more than 4\(hy15\ seconds.
  2028. Record the message sequence using a signal monitor.
  2029.  }
  2030. .T&
  2031. cw(18p) | lw(210p) .
  2032. 2.     {
  2033. CHECK A:
  2034. CONFIRM THAT A CALL CANNOT BE INITIATED BY EITHER
  2035. SP 
  2036.  }
  2037. .T&
  2038. cw(18p) | lw(210p) .
  2039. 3.     {
  2040. Arrange for the interruption of the pilot tone to be terminated.
  2041.  }
  2042. .T&
  2043. cw(18p) | lw(210p) .
  2044. 4.     {
  2045. CHECK B:
  2046. CONFIRM THAT A CALL CAN BE INITIATED BY EITHER SP AFTER A
  2047. PERIOD OF 4\(hy15\ SECONDS 
  2048.  }
  2049. .T&
  2050. cw(18p) | lw(210p) .
  2051. 5.     {
  2052. CHECK C:
  2053. WAS THE MESSAGE SEQUENCE AS
  2054. ABOVE? |  |  |  |  |  |  
  2055.  }
  2056. _
  2057. .TE
  2058. .nr PS 9
  2059. .RT
  2060. .ad r
  2061. \fBTableau [T13.783], p.\fR 
  2062. .sp 1P
  2063. .RT
  2064. .ad b
  2065. .RT
  2066. .LP
  2067. .bp
  2068. .ce
  2069. \fBH.T. [T14.783]\fR 
  2070. .ce
  2071. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2072. .ps 9
  2073. .vs 11
  2074. .nr VS 11
  2075. .nr PS 9
  2076. .TS
  2077. center box;
  2078. lw(228p) .
  2079. TEST NUMBER:\ 1.4.1
  2080. _
  2081. .T&
  2082. lw(228p) .
  2083. REFERENCE:\ Q.724 \(sc 7.5
  2084. _
  2085. .T&
  2086. lw(228p) .
  2087.  {
  2088. TITLE:\ Continuity check test call
  2089.  }
  2090. _
  2091. .T&
  2092. lw(228p) .
  2093.  {
  2094. SUBTITLE:\ CCTC received: Successful
  2095.  }
  2096. _
  2097. .T&
  2098. lw(228p) .
  2099.  {
  2100. PURPOSE:\ To verify th
  2101. at the continuity test call procedure can be
  2102. correctly performed
  2103.  }
  2104. _
  2105. .T&
  2106. lw(228p) .
  2107.  {
  2108. PRE\(hyTEST CONDITIONS:\ Circuit must be idle
  2109.  }
  2110. _
  2111. .T&
  2112. cw(72p) | cw(84p) | cw(72p) .
  2113. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  2114. _
  2115. .T&
  2116. lw(228p) .
  2117. EXPECTED MESSAGE SEQUENCE:
  2118. .T&
  2119. lw(72p) | lw(84p) | lw(72p) .
  2120. SP\ \ A        SP\ \ B
  2121. .T&
  2122. lw(72p) | cw(84p) | lw(72p) .
  2123.     <-------------------------    CCR
  2124. .T&
  2125. lw(72p) | cw(84p) | lw(72p) .
  2126.      {
  2127. |
  2128.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2129.  }    Check tone
  2130. .T&
  2131. lw(72p) | cw(84p) | lw(72p) .
  2132.      {
  2133. \f | fR
  2134.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2135.  }    
  2136. .T&
  2137. lw(72p) | cw(84p) | lw(72p) .
  2138.     <-------------------------    CLF
  2139. .T&
  2140. lw(72p) | cw(84p) | lw(72p) .
  2141. RLG    ------------------------->    
  2142. _
  2143. .T&
  2144. lw(72p) | cw(84p) | lw(72p) .
  2145. TEST DESCRIPTION        
  2146. _
  2147. .T&
  2148. cw(18p) | lw(210p) .
  2149. 1.     {
  2150. Initiate the continuity test call procedure at SP\ B.
  2151. Record the message sequence using a signal monitor.
  2152.  }
  2153. .T&
  2154. cw(18p) | lw(210p) .
  2155. 2.     {
  2156. CHECK A:
  2157. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2158.  }
  2159. .T&
  2160. cw(18p) | lw(210p) .
  2161. 3.     {
  2162. CHECK B:
  2163. WAS THE MESSAGE SEQUENCE AS
  2164. ABOVE? |  |  |  |  |  | 
  2165.  }
  2166. _
  2167. .TE
  2168. .nr PS 9
  2169. .RT
  2170. .ad r
  2171. \fBTableau [T14.783], p.\fR 
  2172. .sp 1P
  2173. .RT
  2174. .ad b
  2175. .RT
  2176. .LP
  2177. .bp
  2178. .ce
  2179. \fBH.T. [T15.783]\fR 
  2180. .ce
  2181. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2182. .ps 9
  2183. .vs 11
  2184. .nr VS 11
  2185. .nr PS 9
  2186. .TS
  2187. center box;
  2188. lw(228p) .
  2189. TEST NUMBER:\ 1.4.2
  2190. _
  2191. .T&
  2192. lw(228p) .
  2193. REFERENCE:\ Q.724 \(sc 7.5
  2194. _
  2195. .T&
  2196. lw(228p) .
  2197.  {
  2198. TITLE:\ Continuity check test call
  2199.  }
  2200. _
  2201. .T&
  2202. lw(228p) .
  2203.  {
  2204. SUBTITLE:\ CCTC sent: successful
  2205.  }
  2206. _
  2207. .T&
  2208. lw(228p) .
  2209.  {
  2210. PURPOSE:\ To verify th
  2211. at the continuity test call procedure can be
  2212. correctly performed 
  2213.  }
  2214. _
  2215. .T&
  2216. lw(228p) .
  2217.  {
  2218. PRE\(hyTEST CONDITIONS:\ Circuit must be idle
  2219.  }
  2220. _
  2221. .T&
  2222. cw(72p) | cw(84p) | cw(72p) .
  2223. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  2224. _
  2225. .T&
  2226. lw(228p) .
  2227. EXPECTED MESSAGE SEQUENCE:
  2228. .T&
  2229. lw(72p) | lw(84p) | lw(72p) .
  2230. SP\ \ A        SP\ \ B
  2231. .T&
  2232. lw(72p) | cw(84p) | lw(72p) .
  2233. CCR    ------------------------->    
  2234. .T&
  2235. lw(72p) | cw(84p) | lw(72p) .
  2236. Check Tone     {
  2237. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy |
  2238. |
  2239.  }    
  2240. .T&
  2241. lw(72p) | cw(84p) | lw(72p) .
  2242.      {
  2243. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy | f | fR
  2244.  }    
  2245. .T&
  2246. lw(72p) | cw(84p) | lw(72p) .
  2247. CLF    ------------------------->    
  2248. .T&
  2249. lw(72p) | cw(84p) | lw(72p) .
  2250.     <-------------------------    RLG
  2251. _
  2252. .T&
  2253. lw(72p) | cw(84p) | lw(72p) .
  2254. TEST DESCRIPTION        
  2255. _
  2256. .T&
  2257. cw(18p) | lw(210p) .
  2258. 1.     {
  2259. Initiate the continuity test call procedure at SP A.
  2260. Record the message sequence using a signal monitor.
  2261.  }
  2262. .T&
  2263. cw(18p) | lw(210p) .
  2264. 2.     {
  2265. CHECK A:
  2266. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2267.  }
  2268. .T&
  2269. cw(18p) | lw(210p) .
  2270. 3.     {
  2271. CHECK B:
  2272. WAS THE MESSAGE SEQUENCE AS
  2273. ABOVE? |  |  |  |  |  | 
  2274.  }
  2275. _
  2276. .TE
  2277. .nr PS 9
  2278. .RT
  2279. .ad r
  2280. \fBTableau [T15.783], p.\fR 
  2281. .sp 1P
  2282. .RT
  2283. .ad b
  2284. .RT
  2285. .LP
  2286. .bp
  2287. .ce
  2288. \fBH.T. [T16.783]\fR 
  2289. .ce
  2290. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2291. .ps 9
  2292. .vs 11
  2293. .nr VS 11
  2294. .nr PS 9
  2295. .TS
  2296. center box;
  2297. lw(228p) .
  2298. TEST NUMBER:\ 1.4.3
  2299. _
  2300. .T&
  2301. lw(228p) .
  2302. REFERENCE:\ Q.724 \(sc 7.5
  2303. _
  2304. .T&
  2305. lw(228p) .
  2306.  {
  2307. TITLE:\ Continuity check test call
  2308.  }
  2309. _
  2310. .T&
  2311. lw(228p) .
  2312.  {
  2313. SUBTITLE:\ CCTC received: unsuccessful
  2314.  }
  2315. _
  2316. .T&
  2317. lw(228p) .
  2318.  {
  2319. PURPOSE:\ To verify tha
  2320. t the continuity check procedure can be
  2321. correctly received 
  2322.  }
  2323. _
  2324. .T&
  2325. lw(228p) .
  2326.  {
  2327. PRE\(hyTEST CONDITIONS:\ Ensure th
  2328. at no backward check tone is
  2329. detected within the specified time out
  2330.  }
  2331. _
  2332. .T&
  2333. cw(72p) | cw(84p) | cw(72p) .
  2334. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  2335. _
  2336. .T&
  2337. lw(228p) .
  2338. EXPECTED MESSAGE SEQUENCE:
  2339. .T&
  2340. lw(72p) | lw(84p) | lw(72p) .
  2341. SP\ \ A        \fB\(em\ \fR SP\ \ B
  2342. .T&
  2343. lw(72p) | lw(84p) | lw(72p) .
  2344.     <-------------------------    \fB\(em\ \fR CCR
  2345. .T&
  2346. lw(72p) | lw(84p) | lw(72p) .
  2347.      {
  2348. |
  2349.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2350.  }    \fB\(em\ \fR Check tone
  2351. .T&
  2352. lw(72p) | lw(84p) | lw(72p) .
  2353.      {
  2354. \f | fR
  2355.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2356.  }    
  2357. .T&
  2358. lw(72p) | lw(84p) | lw(72p) .
  2359.     <-------------------------    \(em\ CCF
  2360. .T&
  2361. lw(72p) | lw(84p) | lw(72p) .
  2362.         \ |
  2363. .T&
  2364. lw(72p) | rw(84p) | lw(72p) .
  2365.     1\(hy3 minutes    \ |  \ T10
  2366. .T&
  2367. lw(72p) | rw(84p) | lw(72p) .
  2368.         \ |
  2369. .T&
  2370. lw(72p) | lw(84p) | lw(72p) .
  2371.     <-------------------------    \(em\ CCR
  2372. .T&
  2373. lw(72p) | lw(84p) | lw(72p) .
  2374.      {
  2375. |
  2376.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2377.  }    \ \ Check tone
  2378. .T&
  2379. lw(72p) | lw(84p) | lw(72p) .
  2380.      {
  2381. \f | fR
  2382.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2383.  }    
  2384. .T&
  2385. lw(72p) | lw(84p) | lw(72p) .
  2386.     <-------------------------    \(em\ CCF
  2387. .T&
  2388. lw(72p) | lw(84p) | lw(72p) .
  2389.         \ |
  2390. .T&
  2391. lw(72p) | rw(84p) | lw(72p) .
  2392. Maintenance staff alerted    1\(hy3 minutes    \ |  \ T10
  2393. .T&
  2394. lw(72p) | rw(84p) | lw(72p) .
  2395.         \ |
  2396. .T&
  2397. lw(72p) | lw(84p) | lw(72p) .
  2398.     <-------------------------    \(em\ CCR
  2399. .T&
  2400. lw(72p) | lw(84p) | lw(72p) .
  2401.      {
  2402. |
  2403.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2404.  }    \ \ Check tone
  2405. .T&
  2406. lw(72p) | lw(84p) | lw(72p) .
  2407.      {
  2408. \f | fR
  2409.  | (hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2410.  }    
  2411. .T&
  2412. lw(72p) | lw(84p) | lw(72p) .
  2413.     <-------------------------    \ \ CCF
  2414. _
  2415. .T&
  2416. lw(72p) | lw(84p) | lw(72p) .
  2417. TEST DESCRIPTION        
  2418. _
  2419. .T&
  2420. cw(18p) | lw(210p) .
  2421. 1.     {
  2422. Initiate the continuity test call procedure at SP\ B.
  2423. Record the message sequence using a signal monitor.
  2424.  }
  2425. .T&
  2426. cw(18p) | lw(210p) .
  2427. 2.     {
  2428. CHECK A:
  2429. WAS THE SECOND CONTINUITY CHECK INITIATED WITHIN\ 1 TO\ 3
  2430. MINUTES? |  |  |  |  |  | 
  2431.  }
  2432. .T&
  2433. cw(18p) | lw(210p) .
  2434. 3.     {
  2435. CHECK B:
  2436. WERE THE MAINTENANCE STAFF ALERTED ON FAILURE OF THE SECOND
  2437. CONTINUITY CHECK? |  |  |  |  |  | 
  2438.  }
  2439. .T&
  2440. cw(18p) | lw(210p) .
  2441. 4.     {
  2442. CHECK C:
  2443. WAS THE CHECK REPEATED AT INTERVALS OF 1 TO
  2444. 3\ MINUTES? |  |  |  |  |  | 
  2445.  }
  2446. .T&
  2447. cw(18p) | lw(210p) .
  2448. 5.     {
  2449. CHECK D:
  2450. WAS THE MESSAGE SEQUENCE AS
  2451. ABOVE? |  |  |  |  |  | 
  2452.  }
  2453. _
  2454. .TE
  2455. .nr PS 9
  2456. .RT
  2457. .ad r
  2458. \fBTableau [T16.783], p.\fR 
  2459. .sp 1P
  2460. .RT
  2461. .ad b
  2462. .RT
  2463. .LP
  2464. .bp
  2465. .ce
  2466. \fBH.T. [T17.783]\fR 
  2467. .ce
  2468. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2469. .ps 9
  2470. .vs 11
  2471. .nr VS 11
  2472. .nr PS 9
  2473. .TS
  2474. center box;
  2475. lw(228p) .
  2476. TEST NUMBER:\ 1.4.4
  2477. _
  2478. .T&
  2479. lw(228p) .
  2480. REFERENCE:\ Q.724 \(sc 7.5.3
  2481. _
  2482. .T&
  2483. lw(228p) .
  2484.  {
  2485. TITLE:\ Continuity check test call
  2486.  }
  2487. _
  2488. .T&
  2489. lw(228p) .
  2490.  {
  2491. SUBTITLE:\ CCTC sent: unsuccessful
  2492.  }
  2493. _
  2494. .T&
  2495. lw(228p) .
  2496.  {
  2497. PURPOSE:\ To verify th
  2498. at the continuity test call procedure can be
  2499. correctly invoked 
  2500.  }
  2501. _
  2502. .T&
  2503. lw(228p) .
  2504.  {
  2505. PRE\(hyTEST CONDITIONS:\ Ensure th
  2506. at no backward tone is detected
  2507. within the specified timeout 
  2508.  }
  2509. _
  2510. .T&
  2511. cw(72p) | cw(84p) | cw(72p) .
  2512. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  2513. _
  2514. .T&
  2515. lw(228p) .
  2516. EXPECTED MESSAGE SEQUENCE:
  2517. .T&
  2518. lw(72p) | lw(84p) | lw(72p) .
  2519. SP\ \ A        SP\ \ B
  2520. .T&
  2521. lw(72p) | cw(84p) | lw(72p) .
  2522. CCR    ------------------------->    
  2523. .T&
  2524. lw(72p) | cw(84p) | lw(72p) .
  2525. Check tone     {
  2526. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy |
  2527. |
  2528.  }    
  2529. .T&
  2530. lw(72p) | cw(84p) | lw(72p) .
  2531.      {
  2532. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy | f | fR
  2533.  }    
  2534. .T&
  2535. lw(72p) | cw(84p) | lw(72p) .
  2536. CCF\ \ \(em    ------------------------->    
  2537. .T&
  2538. lw(72p) | cw(84p) | lw(72p) .
  2539.  {
  2540. \fBT10\fR
  2541. |  \ 
  2542. T10\ \ |  1\(hy3 minutes
  2543. \fBT10\fR
  2544. |  \ 
  2545.  }        
  2546. .T&
  2547. lw(72p) | cw(84p) | lw(72p) .
  2548. CCR\ \ \(em    ------------------------->    
  2549. .T&
  2550. lw(72p) | cw(84p) | lw(72p) .
  2551.         
  2552. .T&
  2553. lw(72p) | cw(84p) | lw(72p) .
  2554. Check tone     {
  2555. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy |
  2556. |
  2557.  }    
  2558. .T&
  2559. lw(72p) | cw(84p) | lw(72p) .
  2560.      {
  2561. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy | f | fR
  2562.  }    
  2563. .T&
  2564. lw(72p) | cw(84p) | lw(72p) .
  2565. CCF\ \ \(em    ------------------------->    
  2566. .T&
  2567. lw(72p) | lw(84p) | lw(72p) .
  2568.  {
  2569. \fBT10\fR
  2570. |  \ 
  2571. T10\ \ |  1\(hy3 minutes
  2572. \fBT10\fR
  2573. |
  2574.  }        Maintenance staff alerted
  2575. .T&
  2576. lw(72p) | cw(84p) | lw(72p) .
  2577. CCR\ \ \(em    ------------------------->    
  2578. .T&
  2579. lw(72p) | cw(84p) | lw(72p) .
  2580. Check tone     {
  2581. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy |
  2582. |
  2583.  }    
  2584. .T&
  2585. lw(72p) | cw(84p) | lw(72p) .
  2586.      {
  2587. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy | f | fR
  2588.  }    
  2589. .T&
  2590. lw(72p) | cw(84p) | lw(72p) .
  2591. CCF    ------------------------->    
  2592. .T&
  2593. lw(72p) | cw(84p) | lw(72p) .
  2594.         
  2595. _
  2596. .T&
  2597. lw(72p) | cw(84p) | lw(72p) .
  2598. TEST DESCRIPTION        
  2599. _
  2600. .T&
  2601. cw(18p) | lw(210p) .
  2602. 1.     {
  2603. Initiate the continuity test call procedure at SP\ A.
  2604. Record the message sequence using a signal monitor.
  2605.  }
  2606. .T&
  2607. cw(18p) | lw(210p) .
  2608. 2.     {
  2609. CHECK A:
  2610. WAS THE SECOND CONTINUITY CHECK INITIATED WITHIN\ 1 TO
  2611. 3\ MINUTES? |  |  |  |  |  |  
  2612.  }
  2613. .T&
  2614. cw(18p) | lw(210p) .
  2615. 3.     {
  2616. CHECK B:
  2617. WERE THE MAINTENANCE STAFF ALERTED ON FAILURE OF THE SECOND
  2618. CONTINUITY CHECK? |  |  |  |  |  |  
  2619.  }
  2620. .T&
  2621. cw(18p) | lw(210p) .
  2622. 4.     {
  2623. CHECK C:
  2624. WAS THE CHECK REPEATED AT INTERVALS OF 1 TO
  2625. 3\ MINUTES? |  |  |  |  |  |  
  2626.  }
  2627. .T&
  2628. cw(18p) | lw(210p) .
  2629. 5.     {
  2630. CHECK D:
  2631. WAS THE MESSAGE SEQUENCE AS
  2632. ABOVE? |  |  |  |  |  |  
  2633.  }
  2634. _
  2635. .TE
  2636. .nr PS 9
  2637. .RT
  2638. .ad r
  2639. \fBTableau [T17.783], p.\fR 
  2640. .sp 1P
  2641. .RT
  2642. .ad b
  2643. .RT
  2644. .LP
  2645. .bp
  2646. .ce
  2647. \fBH.T. [T18.783]\fR 
  2648. .ce
  2649. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2650. .ps 9
  2651. .vs 11
  2652. .nr VS 11
  2653. .nr PS 9
  2654. .TS
  2655. center box;
  2656. lw(228p) .
  2657. TEST NUMBER:\ 1.5.1
  2658. _
  2659. .T&
  2660. lw(228p) .
  2661. REFERENCE:\ Q.724 \(sc 6.5
  2662. _
  2663. .T&
  2664. lw(228p) .
  2665.  {
  2666. TITLE:\ Receipt of unreasonable information
  2667.  }
  2668. _
  2669. .T&
  2670. lw(228p) .
  2671. SUBTITLE:\ Received
  2672. _
  2673. .T&
  2674. lw(228p) .
  2675.  {
  2676. PURPOSE:
  2677. To verify that the action taken by a signalling point upon
  2678. receipt of unreasonable signalling information is as stated in Q.724
  2679. \(sc\ 6.5 
  2680.  }
  2681. _
  2682. .T&
  2683. lw(228p) .
  2684.  {
  2685. PRE\(hyTEST CONDITIONS:
  2686. a)
  2687. Arrange the data in signalling point B such that CLF, RLG, and UBL
  2688. messages may be initiated
  2689. b)
  2690. The circuit should be idle and unblocked
  2691.  }
  2692. _
  2693. .T&
  2694. cw(72p) | cw(84p) | cw(72p) .
  2695. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  2696. _
  2697. .T&
  2698. lw(228p) .
  2699. EXPECTED MESSAGE SEQUENCE:
  2700. .T&
  2701. lw(72p) | lw(84p) | lw(72p) .
  2702. SP\ \ A        SP\ \ B
  2703. .T&
  2704. lw(72p) | lw(84p) | lw(72p) .
  2705. a)        
  2706. .T&
  2707. lw(72p) | cw(84p) | lw(72p) .
  2708.     <-------------------------    CLF
  2709. .T&
  2710. lw(72p) | cw(84p) | lw(72p) .
  2711. RLG    ------------------------->    
  2712. .T&
  2713. lw(72p) | cw(84p) | lw(72p) .
  2714. b)        
  2715. .T&
  2716. lw(72p) | cw(84p) | lw(72p) .
  2717.     <-------------------------    RLG
  2718. .T&
  2719. lw(72p) | cw(84p) | lw(72p) .
  2720. c)    <-------------------------    UBL
  2721. .T&
  2722. lw(72p) | cw(84p) | lw(72p) .
  2723. UBA    ------------------------->    
  2724. _
  2725. .T&
  2726. lw(72p) | cw(84p) | lw(72p) .
  2727. TEST DESCRIPTION        
  2728. _
  2729. .T&
  2730. cw(18p) | lw(210p) .
  2731. 1.     {
  2732. Arrange for SP B to send a clear forward signal.
  2733.  }
  2734. .T&
  2735. cw(18p) | lw(210p) .
  2736. 2.     {
  2737. CHECK A:
  2738. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2739.  }
  2740. .T&
  2741. cw(18p) | lw(210p) .
  2742. 3.     {
  2743. CHECK B:
  2744. WAS THE MESSAGE SEQUENCE AS IN a)
  2745. ABOVE? |  |  |  |  |  | 
  2746.  }
  2747. .T&
  2748. cw(18p) | lw(210p) .
  2749. 4.     {
  2750. Arrange for SP B to send a release guard signal.
  2751.  }
  2752. .T&
  2753. cw(18p) | lw(210p) .
  2754. 5.     {
  2755. CHECK C:
  2756. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2757.  }
  2758. .T&
  2759. cw(18p) | lw(210p) .
  2760. 6.     {
  2761. CHECK D:
  2762. WAS THE MESSAGE SEQUENCE AS IN b)
  2763. ABOVE? |  |  |  |  |  |  
  2764.  }
  2765. .T&
  2766. cw(18p) | lw(210p) .
  2767. 7.     {
  2768. Arrange for SP B to send an unblocking signal.
  2769.  }
  2770. .T&
  2771. cw(18p) | lw(210p) .
  2772. 8.     {
  2773. CHECK E:
  2774. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2775.  }
  2776. .T&
  2777. cw(18p) | lw(210p) .
  2778. 9.     {
  2779. CHECK F:
  2780. WAS THE MESSAGE SEQUENCE AS IN c)
  2781. ABOVE? |  |  |  |  |  | 
  2782.  }
  2783. .TE
  2784. .LP
  2785.  
  2786. \fINote\fR
  2787. \ \(em\ This test covers only some of the ambiguous messages which could be
  2788. received.
  2789. .nr PS 9
  2790. .RT
  2791. .ad r
  2792. \fBTableau [T18.783], p.\fR 
  2793. .sp 1P
  2794. .RT
  2795. .ad b
  2796. .RT
  2797. .LP
  2798. .bp
  2799. .ce
  2800. \fBH.T. [T19.783]\fR 
  2801. .ce
  2802. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2803. .ps 9
  2804. .vs 11
  2805. .nr VS 11
  2806. .nr PS 9
  2807. .TS
  2808. center box;
  2809. lw(228p) .
  2810. TEST NUMBER:\ 2.1.1
  2811. _
  2812. .T&
  2813. lw(228p) .
  2814. REFERENCE:\ Q.724 \(sc 1
  2815. _
  2816. .T&
  2817. lw(228p) .
  2818.  {
  2819. TITLE:\ Both way circuit selection
  2820.  }
  2821. _
  2822. .T&
  2823. lw(228p) .
  2824.  {
  2825. SUBTITLE:\ IAM sent by controlling SP
  2826.  }
  2827. _
  2828. .T&
  2829. lw(228p) .
  2830.  {
  2831. PURPOSE:
  2832. To verify that signalling point A can initiate an outgoing
  2833. call on a circuit capable of bothway operation when the controlling
  2834. SP is\ A 
  2835.  }
  2836. _
  2837. .T&
  2838. lw(228p) .
  2839.  {
  2840. PRE\(hyTEST CONDITIONS:
  2841. a)
  2842. Called termination is free
  2843. b)
  2844. Circuit selected is capable of bothway operation
  2845. c)
  2846. Circuit selected is as in test number 2.1.2
  2847. d)
  2848. SP A is the controlling signalling point 
  2849.  }
  2850. _
  2851. .T&
  2852. cw(72p) | cw(84p) | cw(72p) .
  2853. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  2854. _
  2855. .T&
  2856. lw(228p) .
  2857. EXPECTED MESSAGE SEQUENCE:
  2858. .T&
  2859. lw(72p) | lw(84p) | lw(72p) .
  2860. SP\ \ A        SP\ \ B
  2861. .T&
  2862. lw(72p) | cw(84p) | lw(72p) .
  2863. IAM    ------------------------->    
  2864. .T&
  2865. lw(72p) | cw(84p) | lw(72p) .
  2866.     <-------------------------    ACM
  2867. .T&
  2868. lw(72p) | cw(84p) | lw(72p) .
  2869.      {
  2870. \f | | fR
  2871. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  2872.  }    Ringing tone
  2873. .T&
  2874. lw(72p) | cw(84p) | lw(72p) .
  2875.     <-------------------------    ANC
  2876. .T&
  2877. lw(72p) | cw(84p) | lw(72p) .
  2878. Speech     {
  2879. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  2880.  }    Speech
  2881. .T&
  2882. lw(72p) | cw(84p) | lw(72p) .
  2883. CLF    ------------------------->    
  2884. .T&
  2885. lw(72p) | cw(84p) | lw(72p) .
  2886.     <-------------------------    RLG
  2887. _
  2888. .T&
  2889. lw(72p) | cw(84p) | lw(72p) .
  2890. TEST DESCRIPTION        
  2891. _
  2892. .T&
  2893. cw(18p) | lw(210p) .
  2894. 1.     {
  2895. Make a call from SP A TO SP B.
  2896. Record the message sequence using a signal monitor.
  2897.  }
  2898. .T&
  2899. cw(18p) | lw(210p) .
  2900. 2.     {
  2901. CHECK A:
  2902. CAN RINGING TONE BE HEARD? |  |  |  |  |  | 
  2903.  }
  2904. .T&
  2905. cw(18p) | lw(210p) .
  2906. 3.     {
  2907. The called party should answer the call.
  2908.  }
  2909. .T&
  2910. cw(18p) | lw(210p) .
  2911. 4.     {
  2912. CHECK B:
  2913. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  2914.  }
  2915. .T&
  2916. cw(18p) | lw(210p) .
  2917. 5.     {
  2918. The calling party should clear the call.
  2919.  }
  2920. .T&
  2921. cw(18p) | lw(210p) .
  2922. 6.     {
  2923. CHECK C:
  2924. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  2925.  }
  2926. .T&
  2927. cw(18p) | lw(210p) .
  2928. 7.     {
  2929. CHECK D:
  2930. WAS THE MESSAGE SEQUENCE AS
  2931. ABOVE? |  |  |  |  |  | 
  2932.  }
  2933. _
  2934. .TE
  2935. .nr PS 9
  2936. .RT
  2937. .ad r
  2938. \fBTableau [T19.783], p.\fR 
  2939. .sp 1P
  2940. .RT
  2941. .ad b
  2942. .RT
  2943. .LP
  2944. .bp
  2945. .ce
  2946. \fBH.T. [T20.783]\fR 
  2947. .ce
  2948. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  2949. .ps 9
  2950. .vs 11
  2951. .nr VS 11
  2952. .nr PS 9
  2953. .TS
  2954. center box;
  2955. lw(228p) .
  2956. TEST NUMBER:\ 2.1.2
  2957. _
  2958. .T&
  2959. lw(228p) .
  2960. REFERENCE:\ Q.724 \(sc 1
  2961. _
  2962. .T&
  2963. lw(228p) .
  2964.  {
  2965. TITLE:\ Bothway circuit selection
  2966.  }
  2967. _
  2968. .T&
  2969. lw(228p) .
  2970.  {
  2971. SUBTITLE:\ IAM sent by non\(hycontrolling SP
  2972.  }
  2973. _
  2974. .T&
  2975. lw(228p) .
  2976.  {
  2977. PURPOSE:
  2978. To verify that signalling point A can initiate an outgoing
  2979. call on a circuit capable of bothway operation when the non\(hycontrolling
  2980. SP is\ A 
  2981.  }
  2982. _
  2983. .T&
  2984. lw(228p) .
  2985.  {
  2986. PRE\(hyTEST CONDITIONS:
  2987. a)
  2988. Called termination is free
  2989. b)
  2990. Circuit selected is capable of bothway operation
  2991. c)
  2992. Circuit selected is as in test number 2.1.1
  2993. d)
  2994. SP B is the controlling signalling point 
  2995.  }
  2996. _
  2997. .T&
  2998. cw(72p) | cw(84p) | cw(72p) .
  2999. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3000. _
  3001. .T&
  3002. lw(228p) .
  3003. EXPECTED MESSAGE SEQUENCE:
  3004. .T&
  3005. lw(72p) | lw(84p) | lw(72p) .
  3006. SP\ \ A        SP\ \ B
  3007. .T&
  3008. lw(72p) | cw(84p) | lw(72p) .
  3009. IAM    ------------------------->    
  3010. .T&
  3011. lw(72p) | cw(84p) | lw(72p) .
  3012.     <-------------------------    ACM
  3013. .T&
  3014. lw(72p) | cw(84p) | lw(72p) .
  3015.      {
  3016. \f | | fR
  3017. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3018.  }    Ringing tone
  3019. .T&
  3020. lw(72p) | cw(84p) | lw(72p) .
  3021.     <-------------------------    ANC
  3022. .T&
  3023. lw(72p) | cw(84p) | lw(72p) .
  3024. Speech     {
  3025. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3026.  }    
  3027. .T&
  3028. lw(72p) | cw(84p) | lw(72p) .
  3029. CLF    ------------------------->    
  3030. .T&
  3031. lw(72p) | cw(84p) | lw(72p) .
  3032.     <-------------------------    RLG
  3033. _
  3034. .T&
  3035. lw(72p) | cw(84p) | lw(72p) .
  3036. TEST DESCRIPTION        
  3037. _
  3038. .T&
  3039. cw(18p) | lw(210p) .
  3040. 1.     {
  3041. Make a call from SP A to SP B.
  3042. Record the message sequence using a signal monitor.
  3043.  }
  3044. .T&
  3045. cw(18p) | lw(210p) .
  3046. 2.     {
  3047. CHECK A:
  3048. CAN RINGING TONE BE HEARD? |  |  |  |  |  | 
  3049.  }
  3050. .T&
  3051. cw(18p) | lw(210p) .
  3052. 3.     {
  3053. The called party should answer the call.
  3054.  }
  3055. .T&
  3056. cw(18p) | lw(210p) .
  3057. 4.     {
  3058. CHECK B:
  3059. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3060.  }
  3061. .T&
  3062. cw(18p) | lw(210p) .
  3063. 5.     {
  3064. The calling party should clear the call.
  3065.  }
  3066. .T&
  3067. cw(18p) | lw(210p) .
  3068. 6.     {
  3069. CHECK C:
  3070. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  3071.  }
  3072. .T&
  3073. cw(18p) | lw(210p) .
  3074. 7.     {
  3075. CHECK D:
  3076. WAS THE MESSAGE SEQUENCE AS
  3077. ABOVE? |  |  |  |  |  | 
  3078.  }
  3079. _
  3080. .TE
  3081. .nr PS 9
  3082. .RT
  3083. .ad r
  3084. \fBTableau [T20.783], p.\fR 
  3085. .sp 1P
  3086. .RT
  3087. .ad b
  3088. .RT
  3089. .LP
  3090. .bp
  3091. .ce
  3092. \fBH.T. [T21.783]\fR 
  3093. .ce
  3094. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3095. .ps 9
  3096. .vs 11
  3097. .nr VS 11
  3098. .nr PS 9
  3099. .TS
  3100. center box;
  3101. lw(228p) .
  3102. TEST NUMBER:\ 2.2.1
  3103. _
  3104. .T&
  3105. lw(228p) .
  3106. REFERENCE:\ Q.724 \(sc 1
  3107. _
  3108. .T&
  3109. lw(228p) .
  3110.  {
  3111. TITLE:\ Called address sending
  3112.  }
  3113. _
  3114. .T&
  3115. lw(228p) .
  3116.  {
  3117. SUBTITLE:\ \*QEN BLOC\*U operation
  3118.  }
  3119. _
  3120. .T&
  3121. lw(228p) .
  3122.  {
  3123. PURPOSE:\ To verify that a call can be successfully established (all
  3124. digits included in the IAM)
  3125.  }
  3126. _
  3127. .T&
  3128. lw(228p) .
  3129.  {
  3130. PRE\(hyTEST CONDITIONS:
  3131. a)
  3132. Called termination is free 
  3133. b)
  3134. The exchange data is arranged such that all digits are included in the
  3135. IAM
  3136.  }
  3137. _
  3138. .T&
  3139. cw(72p) | cw(84p) | cw(72p) .
  3140. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3141. _
  3142. .T&
  3143. lw(228p) .
  3144. EXPECTED MESSAGE SEQUENCE:
  3145. .T&
  3146. lw(72p) | lw(84p) | lw(72p) .
  3147. SP\ \ A        SP\ \ B
  3148. .T&
  3149. lw(72p) | cw(84p) | lw(72p) .
  3150. IAM    ------------------------->    
  3151. .T&
  3152. lw(72p) | cw(84p) | lw(72p) .
  3153.     <-------------------------    ACM
  3154. .T&
  3155. lw(72p) | cw(84p) | lw(72p) .
  3156.      {
  3157. \f | | fR
  3158. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3159.  }    Ringing tone
  3160. .T&
  3161. lw(72p) | cw(84p) | lw(72p) .
  3162.     <-------------------------    ANC
  3163. .T&
  3164. lw(72p) | cw(84p) | lw(72p) .
  3165. Speech     {
  3166. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3167.  }    Speech
  3168. .T&
  3169. lw(72p) | cw(84p) | lw(72p) .
  3170. CLF    ------------------------->    
  3171. .T&
  3172. lw(72p) | cw(84p) | lw(72p) .
  3173.     <-------------------------    RLG
  3174. _
  3175. .T&
  3176. lw(72p) | cw(84p) | lw(72p) .
  3177. TEST DESCRIPTION        
  3178. _
  3179. .T&
  3180. cw(18p) | lw(210p) .
  3181. 1.     {
  3182. Make a call from SP A to SP B.
  3183. Record the message sequence using a signal monitor.
  3184.  }
  3185. .T&
  3186. cw(18p) | lw(210p) .
  3187. 2.     {
  3188. CHECK A:
  3189. IS RINGING TONE HEARD? |  |  |  |  |  | 
  3190.  }
  3191. .T&
  3192. cw(18p) | lw(210p) .
  3193. 3.     {
  3194. The called party should answer the call.
  3195.  }
  3196. .T&
  3197. cw(18p) | lw(210p) .
  3198. 4.     {
  3199. CHECK B:
  3200. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3201.  }
  3202. .T&
  3203. cw(18p) | lw(210p) .
  3204. 5.     {
  3205. The calling party should clear the call.
  3206.  }
  3207. .T&
  3208. cw(18p) | lw(210p) .
  3209. 6.     {
  3210. CHECK C:
  3211. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  3212.  }
  3213. .T&
  3214. cw(18p) | lw(210p) .
  3215. 7.     {
  3216. CHECK D:
  3217. WAS THE MESSAGE SEQUENCE AS
  3218. ABOVE? |  |  |  |  |  | 
  3219.  }
  3220. .T&
  3221. cw(18p) | lw(210p) .
  3222. 8.     {
  3223. For validation testing repeat this test in the reverse direction
  3224. Where SPA is in a position to know, by digit analysis that the final digit
  3225. has been sent. Confirm that an End\(hyof\(hypulsing (ST) signal is included in
  3226. the IAM.
  3227.  }
  3228. _
  3229. .TE
  3230. .nr PS 9
  3231. .RT
  3232. .ad r
  3233. \fBTableau [T21.783], p.\fR 
  3234. .sp 1P
  3235. .RT
  3236. .ad b
  3237. .RT
  3238. .LP
  3239. .bp
  3240. .ce
  3241. \fBH.T. [T22.783]\fR 
  3242. .ce
  3243. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3244. .ps 9
  3245. .vs 11
  3246. .nr VS 11
  3247. .nr PS 9
  3248. .TS
  3249. center box;
  3250. lw(228p) .
  3251. TEST NUMBER:\ 2.2.2
  3252. _
  3253. .T&
  3254. lw(228p) .
  3255. REFERENCE:\ Q.724 \(sc 1
  3256. _
  3257. .T&
  3258. lw(228p) .
  3259.  {
  3260. TITLE:\ Called address sending
  3261.  }
  3262. _
  3263. .T&
  3264. lw(228p) .
  3265.  {
  3266. SUBTITLE:\ Overlap operation (with SAM and SAO)
  3267.  }
  3268. _
  3269. .T&
  3270. lw(228p) .
  3271.  {
  3272. PURPOSE:\ To verify that signalling point A can initiate a call using
  3273. an IAM followed by SAM and a SAO
  3274.  }
  3275. _
  3276. .T&
  3277. lw(228p) .
  3278.  {
  3279. PRE\(hyTEST CONDITIONS:
  3280. a)
  3281. Called termination is free 
  3282. b)
  3283. The signalling point data is arranged such that digits are generated
  3284. in an IAM followed by a SAM and a SAO
  3285.  }
  3286. _
  3287. .T&
  3288. cw(72p) | cw(84p) | cw(72p) .
  3289. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3290. _
  3291. .T&
  3292. lw(228p) .
  3293. EXPECTED MESSAGE SEQUENCE:
  3294. .T&
  3295. lw(72p) | lw(84p) | lw(72p) .
  3296. SP\ \ A        SP\ \ B
  3297. .T&
  3298. lw(72p) | cw(84p) | lw(72p) .
  3299. IAM    ------------------------->    
  3300. .T&
  3301. lw(72p) | cw(84p) | lw(72p) .
  3302. SAM    ------------------------->    
  3303. .T&
  3304. lw(72p) | cw(84p) | lw(72p) .
  3305. SAO    ------------------------->    
  3306. .T&
  3307. lw(72p) | cw(84p) | lw(72p) .
  3308.     <-------------------------    ACM
  3309. .T&
  3310. lw(72p) | cw(84p) | lw(72p) .
  3311.      {
  3312. \f | | fR
  3313. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3314.  }    Ringing tone
  3315. .T&
  3316. lw(72p) | cw(84p) | lw(72p) .
  3317.     <-------------------------    ANC
  3318. .T&
  3319. lw(72p) | cw(84p) | lw(72p) .
  3320. Speech     {
  3321. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3322.  }    Speech
  3323. .T&
  3324. lw(72p) | cw(84p) | lw(72p) .
  3325. CLF    ------------------------->    
  3326. .T&
  3327. lw(72p) | cw(84p) | lw(72p) .
  3328.     <-------------------------    RLG
  3329. _
  3330. .T&
  3331. lw(72p) | cw(84p) | lw(72p) .
  3332. TEST DESCRIPTION        
  3333. _
  3334. .T&
  3335. cw(18p) | lw(210p) .
  3336. 1.     {
  3337. Make a call from SP A to SP B.
  3338. Record the message sequence using a signal monitor.
  3339.  }
  3340. .T&
  3341. cw(18p) | lw(210p) .
  3342. 2.     {
  3343. CHECK A:
  3344. IS RINGING TONE HEARD? |  |  |  |  |  | 
  3345.  }
  3346. .T&
  3347. cw(18p) | lw(210p) .
  3348. 3.     {
  3349. The called party should answer the call.
  3350.  }
  3351. .T&
  3352. cw(18p) | lw(210p) .
  3353. 4.     {
  3354. CHECK B:
  3355. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3356.  }
  3357. .T&
  3358. cw(18p) | lw(210p) .
  3359. 5.     {
  3360. The calling party should clear the call.
  3361.  }
  3362. .T&
  3363. cw(18p) | lw(210p) .
  3364. 6.     {
  3365. CHECK C:
  3366. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  3367.  }
  3368. .T&
  3369. cw(18p) | lw(210p) .
  3370. 7.     {
  3371. CHECK D:
  3372. WAS THE MESSAGE SEQUENCE AS
  3373. ABOVE? |  |  |  |  |  | 
  3374.  }
  3375. .T&
  3376. cw(18p) | lw(210p) .
  3377. 8.     {
  3378. For validation testing repeat this test in the reverse direction.
  3379. Note\ \(em
  3380. The message flow may not be as above
  3381. (There may be various SAMs and SAOs).
  3382.  }
  3383. .T&
  3384. cw(18p) | lw(210p) .
  3385.      {
  3386. Where SPA is in a position to know by digit analysis that the final digit
  3387. has been sent. Confirm that an end\(hyof\(hypulsing (ST) signal is included in
  3388. the last address message.
  3389.  }
  3390. _
  3391. .TE
  3392. .nr PS 9
  3393. .RT
  3394. .ad r
  3395. \fBTableau [T22.783], p.\fR 
  3396. .sp 1P
  3397. .RT
  3398. .ad b
  3399. .RT
  3400. .LP
  3401. .bp
  3402. .ce
  3403. \fBH.T. [T23.783]\fR 
  3404. .ce
  3405. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3406. .ps 9
  3407. .vs 11
  3408. .nr VS 11
  3409. .nr PS 9
  3410. .TS
  3411. center box;
  3412. lw(228p) .
  3413. TEST NUMBER:\ 2.3.1
  3414. _
  3415. .T&
  3416. lw(228p) .
  3417.  {
  3418. REFERENCE:\ Q.724 \(sc 1.6 and 1.10
  3419.  }
  3420. _
  3421. .T&
  3422. lw(228p) .
  3423.  {
  3424. TITLE:\ Successful call set\(hyup
  3425.  }
  3426. _
  3427. .T&
  3428. lw(228p) .
  3429.  {
  3430. SUBTITLE:\ Ordinary call (with various ACM and ANS)
  3431.  }
  3432. _
  3433. .T&
  3434. lw(228p) .
  3435.  {
  3436. PURPOSE:
  3437. To verify that a call can be successfully completed using
  3438. various combinations of address complete messages and answer
  3439. messages
  3440.  }
  3441. _
  3442. .T&
  3443. lw(228p) .
  3444.  {
  3445. PRE\(hyTEST CONDITIONS:\ Called termination is free
  3446.  }
  3447. _
  3448. .T&
  3449. cw(72p) | cw(84p) | cw(72p) .
  3450. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  3451. _
  3452. .T&
  3453. lw(228p) .
  3454. EXPECTED MESSAGE SEQUENCE:
  3455. .T&
  3456. lw(72p) | lw(84p) | lw(72p) .
  3457. SP\ \ A        SP\ \ B
  3458. .T&
  3459. lw(72p) | cw(84p) | lw(72p) .
  3460. IAM    ------------------------->    
  3461. .T&
  3462. lw(72p) | cw(84p) | lw(72p) .
  3463.     <-------------------------    ACM
  3464. .T&
  3465. lw(72p) | cw(84p) | lw(72p) .
  3466.      {
  3467. \f | | fR
  3468. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3469.  }    Ringing tone
  3470. .T&
  3471. lw(72p) | cw(84p) | lw(72p) .
  3472.     <-------------------------    ANC
  3473. .T&
  3474. lw(72p) | cw(84p) | lw(72p) .
  3475. Speech     {
  3476. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3477.  }    Speech
  3478. .T&
  3479. lw(72p) | cw(84p) | lw(72p) .
  3480. CLF    ------------------------->    
  3481. .T&
  3482. lw(72p) | cw(84p) | lw(72p) .
  3483.     <-------------------------    RLG
  3484. _
  3485. .T&
  3486. lw(72p) | cw(84p) | lw(72p) .
  3487. TEST DESCRIPTION        
  3488. _
  3489. .T&
  3490. cw(18p) | lw(210p) .
  3491. \ 1.     {
  3492. Make a call from SP A to SP B.
  3493. Record the message sequence using a signal monitor.
  3494.  }
  3495. .T&
  3496. cw(18p) | lw(210p) .
  3497. \ 2.     {
  3498. CHECK A:
  3499. CAN RINGING TONE BE HEARD? |  |  |  |  |  | 
  3500.  }
  3501. .T&
  3502. cw(18p) | lw(210p) .
  3503. \ 3.     {
  3504. The called party should answer the call.
  3505.  }
  3506. .T&
  3507. cw(18p) | lw(210p) .
  3508. \ 4.     {
  3509. CHECK B:
  3510. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3511.  }
  3512. .T&
  3513. cw(18p) | lw(210p) .
  3514. \ 5.     {
  3515. The calling party should clear the call.
  3516.  }
  3517. .T&
  3518. cw(18p) | lw(210p) .
  3519. \ 6.     {
  3520. CHECK C:
  3521. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  3522.  }
  3523. .T&
  3524. cw(18p) | lw(210p) .
  3525. \ 7.     {
  3526. CHECK D:
  3527. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  3528.  }
  3529. .T&
  3530. cw(18p) | lw(210p) .
  3531. \ 8.     {
  3532. Repeat steps 1\(hy7 with all combinations of bits A&B in the address
  3533. complete message.
  3534.  }
  3535. .T&
  3536. cw(18p) | lw(210p) .
  3537. \ 9.     {
  3538. Repeat steps 1\(hy8 with ANC replaced with an ANN.
  3539.  }
  3540. .T&
  3541. cw(18p) | lw(210p) .
  3542. 10.     {
  3543. Repeat this test in the reverse direction.
  3544.  }
  3545. _
  3546. .TE
  3547. .nr PS 9
  3548. .RT
  3549. .ad r
  3550. \fBTableau [T23.783], p.\fR 
  3551. .sp 1P
  3552. .RT
  3553. .ad b
  3554. .RT
  3555. .LP
  3556. .bp
  3557. .ce
  3558. \fBH.T. [T24.783]\fR 
  3559. .ce
  3560. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3561. .ps 9
  3562. .vs 11
  3563. .nr VS 11
  3564. .nr PS 9
  3565. .TS
  3566. center box;
  3567. lw(228p) .
  3568. TEST NUMBER:\ 2.3.2
  3569. _
  3570. .T&
  3571. lw(228p) .
  3572. REFERENCE:\ Q.724 \(sc 1
  3573. _
  3574. .T&
  3575. lw(228p) .
  3576.  {
  3577. TITLE:\ Successful call set\(hyup
  3578.  }
  3579. _
  3580. .T&
  3581. lw(228p) .
  3582.  {
  3583. SUBTITLE:\ Call switched via a satellite
  3584.  }
  3585. _
  3586. .T&
  3587. lw(228p) .
  3588.  {
  3589. PURPOSE:\ To verify the satellite indicator in the initial address
  3590. message is correctly set
  3591.  }
  3592. _
  3593. .T&
  3594. lw(228p) .
  3595.  {
  3596. PRE\(hyTEST CONDITIONS:
  3597. a)
  3598. Called termination is free 
  3599. b)
  3600. The signalling point data is arranged such that the call is switched via a satellite connection or has a satellite connection already included in the
  3601. path 
  3602.  }
  3603. _
  3604. .T&
  3605. cw(72p) | cw(84p) | cw(72p) .
  3606. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3607. _
  3608. .T&
  3609. lw(228p) .
  3610. EXPECTED MESSAGE SEQUENCE:
  3611. .T&
  3612. lw(72p) | lw(84p) | lw(72p) .
  3613. SP\ \ A        SP\ \ B
  3614. .T&
  3615. lw(72p) | cw(84p) | lw(72p) .
  3616. IAM    ------------------------->    
  3617. .T&
  3618. lw(72p) | cw(84p) | lw(72p) .
  3619.     <-------------------------    ACM
  3620. .T&
  3621. lw(72p) | cw(84p) | lw(72p) .
  3622.      {
  3623. \f | | fR
  3624. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3625.  }    Ringing tone
  3626. .T&
  3627. lw(72p) | cw(84p) | lw(72p) .
  3628.     <-------------------------    ANC
  3629. .T&
  3630. lw(72p) | cw(84p) | lw(72p) .
  3631. Speech     {
  3632. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3633.  }    Speech
  3634. .T&
  3635. lw(72p) | cw(84p) | lw(72p) .
  3636. CLF    ------------------------->    
  3637. .T&
  3638. lw(72p) | cw(84p) | lw(72p) .
  3639.     <-------------------------    RLG
  3640. _
  3641. .T&
  3642. lw(72p) | cw(84p) | lw(72p) .
  3643. TEST DESCRIPTION        
  3644. _
  3645. .T&
  3646. cw(18p) | lw(210p) .
  3647. 1.     {
  3648. Make a call from SP A to SP B.
  3649. Record the message sequence using a signal monitor.
  3650.  }
  3651. .T&
  3652. cw(18p) | lw(210p) .
  3653. 2.     {
  3654. CHECK A:
  3655. IS RINGING TONE HEARD? |  |  |  |  |  | 
  3656.  }
  3657. .T&
  3658. cw(18p) | lw(210p) .
  3659. 3.     {
  3660. The called party should answer the call.
  3661.  }
  3662. .T&
  3663. cw(18p) | lw(210p) .
  3664. 4.     {
  3665. CHECK B:
  3666. IS SPEECH POSSIBLE? |  |  |  |  |  |  |
  3667.  }
  3668. .T&
  3669. cw(18p) | lw(210p) .
  3670. 5.     {
  3671. The calling party should clear the call.
  3672.  }
  3673. .T&
  3674. cw(18p) | lw(210p) .
  3675. 6.     {
  3676. CHECK C:
  3677. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  3678.  }
  3679. .T&
  3680. cw(18p) | lw(210p) .
  3681. 7.     {
  3682. CHECK D:
  3683. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  |  
  3684.  }
  3685. .T&
  3686. cw(18p) | lw(210p) .
  3687. 8.     {
  3688. CHECK E:
  3689. WAS THE SATELLITE INDICATOR BIT IN THE IAM SET
  3690. TO\ 1? |  |  |  |  |  | 
  3691.  }
  3692. .T&
  3693. cw(18p) | lw(210p) .
  3694. 9.     {
  3695. For validation testing repeat this test in the reverse
  3696. direction? |  |  |  |  |  | 
  3697.  }
  3698. _
  3699. .TE
  3700. .nr PS 9
  3701. .RT
  3702. .ad r
  3703. \fBTableau [T24.783], p.\fR 
  3704. .sp 1P
  3705. .RT
  3706. .ad b
  3707. .RT
  3708. .LP
  3709. .bp
  3710. .ce
  3711. \fBH.T. [T25.783]\fR 
  3712. .ce
  3713. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3714. .ps 9
  3715. .vs 11
  3716. .nr VS 11
  3717. .nr PS 9
  3718. .TS
  3719. center box;
  3720. lw(228p) .
  3721. TEST NUMBER:\ 2.3.3
  3722. _
  3723. .T&
  3724. lw(228p) .
  3725. REFERENCE:\ Q.724 \(sc 11
  3726. _
  3727. .T&
  3728. lw(228p) .
  3729.  {
  3730. TITLE:\ Successful call set\(hyup
  3731.  }
  3732. _
  3733. .T&
  3734. lw(228p) .
  3735.  {
  3736. SUBTITLE:\ Test for echo suppressor call set\(hyup
  3737.  }
  3738. _
  3739. .T&
  3740. lw(228p) .
  3741.  {
  3742. PURPOSE:\ To verify that a call can be successfully established with
  3743. the inclusion of echo suppressors
  3744.  }
  3745. _
  3746. .T&
  3747. lw(228p) .
  3748.  {
  3749. PRE\(hyTEST CONDITIONS:
  3750. a)
  3751. Called termination is free 
  3752. b)
  3753. The signalling point data is arranged such that the call is routed
  3754. over a route requiring echo suppressors or already has an
  3755. echo suppressor included in the connection
  3756.  }
  3757. _
  3758. .T&
  3759. cw(72p) | cw(84p) | cw(72p) .
  3760. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3761. _
  3762. .T&
  3763. lw(228p) .
  3764. EXPECTED MESSAGE SEQUENCE:
  3765. .T&
  3766. lw(72p) | lw(84p) | lw(72p) .
  3767. SP\ \ A        SP\ \ B
  3768. .T&
  3769. lw(72p) | cw(84p) | lw(72p) .
  3770. IAM    ------------------------->    
  3771. .T&
  3772. lw(72p) | cw(84p) | lw(72p) .
  3773.     <-------------------------    ACM
  3774. .T&
  3775. lw(72p) | cw(84p) | lw(72p) .
  3776.      {
  3777. \f | | fR
  3778. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3779.  }    Ringing tone
  3780. .T&
  3781. lw(72p) | cw(84p) | lw(72p) .
  3782.     <-------------------------    ANC
  3783. .T&
  3784. lw(72p) | cw(84p) | lw(72p) .
  3785. Speech     {
  3786. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3787.  }    Speech
  3788. .T&
  3789. lw(72p) | cw(84p) | lw(72p) .
  3790. CLF    ------------------------->    
  3791. .T&
  3792. lw(72p) | cw(84p) | lw(72p) .
  3793.     <-------------------------    RLG
  3794. _
  3795. .T&
  3796. lw(72p) | cw(84p) | lw(72p) .
  3797. TEST DESCRIPTION        
  3798. _
  3799. .T&
  3800. cw(18p) | lw(210p) .
  3801. \ 1.     {
  3802. Make a call from SP A to SP B.
  3803. Record the message sequence using a signal monitor.
  3804.  }
  3805. .T&
  3806. cw(18p) | lw(210p) .
  3807. \ 2.     {
  3808. CHECK A:
  3809. IS RINGING TONE HEARD? |  |  |  |  |  | 
  3810.  }
  3811. .T&
  3812. cw(18p) | lw(210p) .
  3813. \ 3.     {
  3814. The called party should answer.
  3815.  }
  3816. .T&
  3817. cw(18p) | lw(210p) .
  3818. \ 4.     {
  3819. CHECK B:
  3820. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3821.  }
  3822. .T&
  3823. cw(18p) | lw(210p) .
  3824. \ 5.     {
  3825. CHECK C:
  3826. IS ECHO PERCEIVED BY EITHER PARTY? |  |  |  |  |  | 
  3827.  }
  3828. .T&
  3829. cw(18p) | lw(210p) .
  3830. \ 6.     {
  3831. The calling party should clear the call.
  3832.  }
  3833. .T&
  3834. cw(18p) | lw(210p) .
  3835. \ 7.     {
  3836. CHECK D:
  3837. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  3838.  }
  3839. .T&
  3840. cw(18p) | lw(210p) .
  3841. \ 8.     {
  3842. CHECK E:
  3843. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  3844.  }
  3845. .T&
  3846. cw(18p) | lw(210p) .
  3847. \ 9.     {
  3848. CHECK F:
  3849. WAS THE MESSAGE INDICATOR BIT G (OUTGOING HALF ECHO
  3850. SUPPRESSOR INCLUDED) IN THE IAM SET TO 1? |  |  |  |  |  | 
  3851.  }
  3852. .T&
  3853. cw(18p) | lw(210p) .
  3854. 10.     {
  3855. CHECK G:
  3856. WAS THE MESSAGE INDICATOR BIT D (INCOMING HALF ECHO
  3857. SUPPRESSOR INCLUDED) IN THE ACM SET TO 1? |  |  |  |  |  | 
  3858.  }
  3859. .T&
  3860. cw(18p) | lw(210p) .
  3861. 11.     {
  3862. For validation testing repeat this test in the reverse
  3863. direction.
  3864.  }
  3865. _
  3866. .TE
  3867. .nr PS 9
  3868. .RT
  3869. .ad r
  3870. \fBTableau [T25.783], p.\fR 
  3871. .sp 1P
  3872. .RT
  3873. .ad b
  3874. .RT
  3875. .LP
  3876. .bp
  3877. .ce
  3878. \fBH.T. [T26.783]\fR 
  3879. .ce
  3880. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  3881. .ps 9
  3882. .vs 11
  3883. .nr VS 11
  3884. .nr PS 9
  3885. .TS
  3886. center box;
  3887. lw(228p) .
  3888. TEST NUMBER:\ 2.3.4
  3889. _
  3890. .T&
  3891. lw(228p) .
  3892. REFERENCE:\ Q.724 \(sc 5
  3893. _
  3894. .T&
  3895. lw(228p) .
  3896.  {
  3897. TITLE:\ Successful call set\(hyup
  3898.  }
  3899. _
  3900. .T&
  3901. lw(228p) .
  3902.  {
  3903. SUBTITLE:\ Blocking and unblocking during a call (initiated)
  3904.  }
  3905. _
  3906. .T&
  3907. lw(228p) .
  3908.  {
  3909. PURPOSE:\ To verify that the circuit blocking and unblocking procedure
  3910. can be correctly initiated during a call
  3911.  }
  3912. _
  3913. .T&
  3914. lw(228p) .
  3915.  {
  3916. PRE\(hyTEST CONDITIONS:\ Called termination is free
  3917.  }
  3918. _
  3919. .T&
  3920. cw(72p) | cw(84p) | cw(72p) .
  3921. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  3922. _
  3923. .T&
  3924. lw(228p) .
  3925. EXPECTED MESSAGE SEQUENCE:
  3926. .T&
  3927. lw(72p) | lw(84p) | lw(72p) .
  3928. SP\ \ A        SP\ \ B
  3929. .T&
  3930. lw(72p) | cw(84p) | lw(72p) .
  3931. IAM    ------------------------->    
  3932. .T&
  3933. lw(72p) | cw(84p) | lw(72p) .
  3934.     <-------------------------    ACM
  3935. .T&
  3936. lw(72p) | cw(84p) | lw(72p) .
  3937.      {
  3938. \f | | fR
  3939. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  3940.  }    Ringing tone
  3941. .T&
  3942. lw(72p) | cw(84p) | lw(72p) .
  3943.     <-------------------------    ANC
  3944. .T&
  3945. lw(72p) | cw(84p) | lw(72p) .
  3946. Speech     {
  3947. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  3948.  }    Speech
  3949. .T&
  3950. lw(72p) | cw(84p) | lw(72p) .
  3951. BLO    ------------------------->    
  3952. .T&
  3953. lw(72p) | cw(84p) | lw(72p) .
  3954.     <-------------------------    BLA
  3955. .T&
  3956. lw(72p) | cw(84p) | lw(72p) .
  3957. CLF    ------------------------->    
  3958. .T&
  3959. lw(72p) | cw(84p) | lw(72p) .
  3960.     <-------------------------    RLG
  3961. .T&
  3962. lw(72p) | cw(84p) | lw(72p) .
  3963. UBL    ------------------------->    
  3964. .T&
  3965. lw(72p) | cw(84p) | lw(72p) .
  3966.     <-------------------------    UBA
  3967. _
  3968. .T&
  3969. lw(72p) | cw(84p) | lw(72p) .
  3970. TEST DESCRIPTION        
  3971. _
  3972. .T&
  3973. cw(18p) | lw(210p) .
  3974. \ 1.     {
  3975. Make a call from SP A to SP B.
  3976. Record the message sequence using a signal monitor.
  3977.  }
  3978. .T&
  3979. cw(18p) | lw(210p) .
  3980. \ 2.     {
  3981. CHECK A:
  3982. CAN RINGING TONE BE HEARD? |  |  |  |  |  | 
  3983.  }
  3984. .T&
  3985. cw(18p) | lw(210p) .
  3986. \ 3.     {
  3987. The called party should answer the call.
  3988.  }
  3989. .T&
  3990. cw(18p) | lw(210p) .
  3991. \ 4.     {
  3992. CHECK B:
  3993. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  3994.  }
  3995. .T&
  3996. cw(18p) | lw(210p) .
  3997. \ 5.     {
  3998. SP A should initiate circuit blocking relating to the circuit used
  3999. for this call.
  4000.  }
  4001. .T&
  4002. cw(18p) | lw(210p) .
  4003. \ 6.     {
  4004. CHECK C:
  4005. IS SPEECH STILL POSSIBLE? |  |  |  |  |  | 
  4006. \fR
  4007.  }
  4008. .T&
  4009. cw(18p) | lw(210p) .
  4010. \ 7.     {
  4011. The calling party should clear the call.
  4012.  }
  4013. .T&
  4014. cw(18p) | lw(210p) .
  4015. \ 8.     {
  4016. CHECK D:
  4017. VERIFY THAT A CALL CAN ONLY BE ORIGINATED ON THIS
  4018. CIRCUIT BY SP\ A? |  |  |  |  |  | 
  4019.  }
  4020. .T&
  4021. cw(18p) | lw(210p) .
  4022. \ 9.     {
  4023. SP A should send an unblocking signal.
  4024.  }
  4025. .T&
  4026. cw(18p) | lw(210p) .
  4027. 10.     {
  4028. CHECK E:
  4029. VERIFY THAT A CALL CAN BE SUCCESSFULLY ORIGINATED
  4030. \fR
  4031. FROM EITHER SP.
  4032.  }
  4033. .T&
  4034. cw(18p) | lw(210p) .
  4035. 11.     {
  4036. CHECK F:
  4037. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4038.  }
  4039. .T&
  4040. cw(18p) | lw(210p) .
  4041. 12.     {
  4042. Repeat this test in the reverse direction.
  4043.  }
  4044. .T&
  4045. cw(18p) | lw(210p) .
  4046.      {
  4047. \fINote\fR
  4048. \ \(em\ The blocking signal may be generated after the call
  4049. has cleared.
  4050.  }
  4051. _
  4052. .TE
  4053. .nr PS 9
  4054. .RT
  4055. .ad r
  4056. \fBTableau [T26.783], p.\fR 
  4057. .sp 1P
  4058. .RT
  4059. .ad b
  4060. .RT
  4061. .LP
  4062. .bp
  4063. .ce
  4064. \fBH.T. [T27.783]\fR 
  4065. .ce
  4066. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4067. .ps 9
  4068. .vs 11
  4069. .nr VS 11
  4070. .nr PS 9
  4071. .TS
  4072. center box;
  4073. lw(228p) .
  4074. TEST NUMBER:\ 2.3.5
  4075. _
  4076. .T&
  4077. lw(228p) .
  4078. REFERENCE:\ Q.724 \(sc 5
  4079. _
  4080. .T&
  4081. lw(228p) .
  4082.  {
  4083. TITLE:\ Successful call set\(hyup
  4084.  }
  4085. _
  4086. .T&
  4087. lw(228p) .
  4088.  {
  4089. SUBTITLE:\ Blocking and unblocking during a call (received)
  4090.  }
  4091. _
  4092. .T&
  4093. lw(228p) .
  4094.  {
  4095. PURPOSE:\ To verify that the circuit blocking and unblocking procedure
  4096. can be correctly received during a call
  4097.  }
  4098. _
  4099. .T&
  4100. lw(228p) .
  4101.  {
  4102. PRE\(hyTEST CONDITIONS:\ Called termination is free
  4103.  }
  4104. _
  4105. .T&
  4106. cw(72p) | cw(84p) | cw(72p) .
  4107. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4108. _
  4109. .T&
  4110. lw(228p) .
  4111. EXPECTED MESSAGE SEQUENCE:
  4112. .T&
  4113. lw(72p) | lw(84p) | lw(72p) .
  4114. SP\ \ A        SP\ \ B
  4115. .T&
  4116. lw(72p) | cw(84p) | lw(72p) .
  4117. IAM    ------------------------->    
  4118. .T&
  4119. lw(72p) | cw(84p) | lw(72p) .
  4120.     <-------------------------    ACM
  4121. .T&
  4122. lw(72p) | cw(84p) | lw(72p) .
  4123.      {
  4124. \f | | fR
  4125. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  4126.  }    Ringing tone
  4127. .T&
  4128. lw(72p) | cw(84p) | lw(72p) .
  4129.     <-------------------------    ANC
  4130. .T&
  4131. lw(72p) | cw(84p) | lw(72p) .
  4132. Speech     {
  4133. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  4134.  }    Speech
  4135. .T&
  4136. lw(72p) | cw(84p) | lw(72p) .
  4137.     <-------------------------    BLO
  4138. .T&
  4139. lw(72p) | cw(84p) | lw(72p) .
  4140. BLA    ------------------------->    
  4141. .T&
  4142. lw(72p) | cw(84p) | lw(72p) .
  4143. CLF    ------------------------->    
  4144. .T&
  4145. lw(72p) | cw(84p) | lw(72p) .
  4146.     <-------------------------    RLG
  4147. .T&
  4148. lw(72p) | cw(84p) | lw(72p) .
  4149.     <-------------------------    UBL
  4150. .T&
  4151. lw(72p) | cw(84p) | lw(72p) .
  4152. UBA    ------------------------->    
  4153. _
  4154. .T&
  4155. lw(72p) | cw(84p) | lw(72p) .
  4156. TEST DESCRIPTION        
  4157. _
  4158. .T&
  4159. cw(18p) | lw(210p) .
  4160. \ 1.     {
  4161. Make a call from SP A to SP B.
  4162. Record the message sequence using a signal monitor.
  4163.  }
  4164. .T&
  4165. cw(18p) | lw(210p) .
  4166. \ 2.     {
  4167. CHECK A:
  4168. CAN RINGING TONE BE HEARD? |  |  |  |  |  | 
  4169.  }
  4170. .T&
  4171. cw(18p) | lw(210p) .
  4172. \ 3.     {
  4173. The called party should answer the call.
  4174.  }
  4175. .T&
  4176. cw(18p) | lw(210p) .
  4177. \ 4.     {
  4178. CHECK B:
  4179. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  4180.  }
  4181. .T&
  4182. cw(18p) | lw(210p) .
  4183. \ 5.     {
  4184. SP B should initiate circuit blocking relating to the circuit used
  4185. for this call.
  4186.  }
  4187. .T&
  4188. cw(18p) | lw(210p) .
  4189. \ 6.     {
  4190. CHECK C:
  4191. IS SPEECH STILL POSSIBLE? |  |  |  |  |  | 
  4192. \fR
  4193.  }
  4194. .T&
  4195. cw(18p) | lw(210p) .
  4196. \ 7.     {
  4197. The calling party should clear the call.
  4198.  }
  4199. .T&
  4200. cw(18p) | lw(210p) .
  4201. \ 8.     {
  4202. CHECK D:
  4203. VERIFY THAT A CALL CAN ONLY BE ORIGINATED ON THIS
  4204. CIRCUIT BY SP\ B? |  |  |  |  |  | 
  4205.  }
  4206. .T&
  4207. cw(18p) | lw(210p) .
  4208. \ 9.     {
  4209. SP B should send an unblocking signal.
  4210.  }
  4211. .T&
  4212. cw(18p) | lw(210p) .
  4213. 10.     {
  4214. CHECK E:
  4215. VERIFY THAT A CALL CAN BE SUCCESSFULLY ORIGINATED
  4216. \fR
  4217. FROM EITHER SP.
  4218.  }
  4219. .T&
  4220. cw(18p) | lw(210p) .
  4221. 11.     {
  4222. CHECK F:
  4223. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4224.  }
  4225. .T&
  4226. cw(18p) | lw(210p) .
  4227. 12.     {
  4228. Repeat this test in the reverse direction.
  4229.  }
  4230. .T&
  4231. cw(18p) | lw(210p) .
  4232.      {
  4233. \fINote\fR
  4234. \ \(em\ The blocking signal may be generated after the call
  4235. has cleared.
  4236.  }
  4237. _
  4238. .TE
  4239. .nr PS 9
  4240. .RT
  4241. .ad r
  4242. \fBTableau [T27.783], p.\fR 
  4243. .sp 1P
  4244. .RT
  4245. .ad b
  4246. .RT
  4247. .LP
  4248. .bp
  4249. .ce
  4250. \fBH.T. [T28.783]\fR 
  4251. .ce
  4252. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4253. .ps 9
  4254. .vs 11
  4255. .nr VS 11
  4256. .nr PS 9
  4257. .TS
  4258. center box;
  4259. lw(228p) .
  4260. TEST NUMBER:\ 3.1
  4261. _
  4262. .T&
  4263. lw(228p) .
  4264. REFERENCE:\ Q.724 \(sc 1.14
  4265. _
  4266. .T&
  4267. lw(228p) .
  4268. TITLE:\ Normal call release
  4269. _
  4270. .T&
  4271. lw(228p) .
  4272.  {
  4273. SUBTITLE:\ Calling party clears before address complete
  4274.  }
  4275. _
  4276. .T&
  4277. lw(228p) .
  4278.  {
  4279. PURPOSE:\ To verify that the calling party can successfully
  4280. release a call prior to receipt of an address complete
  4281. message
  4282.  }
  4283. _
  4284. .T&
  4285. lw(228p) .
  4286. PRE\(hyTEST CONDITIONS:
  4287. _
  4288. .T&
  4289. cw(72p) | cw(84p) | cw(72p) .
  4290. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4291. _
  4292. .T&
  4293. lw(228p) .
  4294. EXPECTED MESSAGE SEQUENCE:
  4295. .T&
  4296. lw(72p) | lw(84p) | lw(72p) .
  4297. SP\ \ A        SP\ \ B
  4298. .T&
  4299. lw(72p) | cw(84p) | lw(72p) .
  4300. IAM    ------------------------->    
  4301. .T&
  4302. lw(72p) | cw(84p) | lw(72p) .
  4303. CLF    ------------------------->    
  4304. .T&
  4305. lw(72p) | cw(84p) | lw(72p) .
  4306.     <-------------------------    RLG
  4307. _
  4308. .T&
  4309. lw(72p) | cw(84p) | lw(72p) .
  4310. TEST DESCRIPTION        
  4311. _
  4312. .T&
  4313. cw(18p) | lw(210p) .
  4314. 1.     {
  4315. Make a call from SP A to SP B.
  4316. Record the message sequence using a signal monitor.
  4317.  }
  4318. .T&
  4319. cw(18p) | lw(210p) .
  4320. 2.     {
  4321. The calling party should clear the call prior to receipt of the
  4322. address complete signal.
  4323.  }
  4324. .T&
  4325. cw(18p) | lw(210p) .
  4326. 3.     {
  4327. CHECK A:
  4328. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  4329.  }
  4330. .T&
  4331. cw(18p) | lw(210p) .
  4332. 4.     {
  4333. CHECK B:
  4334. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4335.  }
  4336. .T&
  4337. cw(18p) | lw(210p) .
  4338. 5.     {
  4339. Repeat this test in the reverse direction.
  4340.  }
  4341. _
  4342. .TE
  4343. .nr PS 9
  4344. .RT
  4345. .ad r
  4346. \fBTableau [T28.783], p.\fR 
  4347. .sp 1P
  4348. .RT
  4349. .ad b
  4350. .RT
  4351. .LP
  4352. .bp
  4353. .ce
  4354. \fBH.T. [T29.783]\fR 
  4355. .ce
  4356. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4357. .ps 9
  4358. .vs 11
  4359. .nr VS 11
  4360. .nr PS 9
  4361. .TS
  4362. center box;
  4363. lw(228p) .
  4364. TEST NUMBER:\ 3.2
  4365. _
  4366. .T&
  4367. lw(228p) .
  4368. REFERENCE:\ Q.724 \(sc 1.14
  4369. _
  4370. .T&
  4371. lw(228p) .
  4372. TITLE:\ Normal call release
  4373. _
  4374. .T&
  4375. lw(228p) .
  4376.  {
  4377. SUBTITLE:\ Calling party clears before answer
  4378.  }
  4379. _
  4380. .T&
  4381. lw(228p) .
  4382.  {
  4383. PURPOSE:\ To verify that the calling party can successfully
  4384. release a call prior to receipt of answer
  4385.  }
  4386. _
  4387. .T&
  4388. lw(228p) .
  4389.  {
  4390. PRE\(hyTEST CONDITIONS:\ Called termination is free
  4391.  }
  4392. _
  4393. .T&
  4394. cw(72p) | cw(84p) | cw(72p) .
  4395. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4396. _
  4397. .T&
  4398. lw(228p) .
  4399. EXPECTED MESSAGE SEQUENCE:
  4400. .T&
  4401. lw(72p) | lw(84p) | lw(72p) .
  4402. SP\ \ A        SP\ \ B
  4403. .T&
  4404. lw(72p) | cw(84p) | lw(72p) .
  4405. IAM    ------------------------->    
  4406. .T&
  4407. lw(72p) | cw(84p) | lw(72p) .
  4408.     <-------------------------    ACM
  4409. .T&
  4410. lw(72p) | cw(84p) | lw(72p) .
  4411.      {
  4412. \f | | fR
  4413. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  4414.  }    Ringing tone
  4415. .T&
  4416. lw(72p) | cw(84p) | lw(72p) .
  4417. CLF    ------------------------->    
  4418. .T&
  4419. lw(72p) | cw(84p) | lw(72p) .
  4420.     <-------------------------    RLG
  4421. _
  4422. .T&
  4423. lw(72p) | cw(84p) | lw(72p) .
  4424. TEST DESCRIPTION        
  4425. _
  4426. .T&
  4427. cw(18p) | lw(210p) .
  4428. 1.     {
  4429. Make a call from SP A to SP B.
  4430. Record the message sequence using a signal monitor.
  4431.  }
  4432. .T&
  4433. cw(18p) | lw(210p) .
  4434. 2.     {
  4435. CHECK A:
  4436. IS RINGING TONE HEARD? |  |  |  |  |  | 
  4437.  }
  4438. .T&
  4439. cw(18p) | lw(210p) .
  4440. 3.     {
  4441. The calling party should clear the call prior to receipt of an
  4442. answer signal.
  4443.  }
  4444. .T&
  4445. cw(18p) | lw(210p) .
  4446. 4.     {
  4447. CHECK B:
  4448. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  4449.  }
  4450. .T&
  4451. cw(18p) | lw(210p) .
  4452. 5.     {
  4453. CHECK C:
  4454. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4455.  }
  4456. .T&
  4457. cw(18p) | lw(210p) .
  4458. 6.     {
  4459. For validation testing this test should be repeated in the reverse
  4460. direction.
  4461.  }
  4462. _
  4463. .TE
  4464. .nr PS 9
  4465. .RT
  4466. .ad r
  4467. \fBTableau [T29.783], p.\fR 
  4468. .sp 1P
  4469. .RT
  4470. .ad b
  4471. .RT
  4472. .LP
  4473. .bp
  4474. .ce
  4475. \fBH.T. [T30.783]\fR 
  4476. .ce
  4477. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4478. .ps 9
  4479. .vs 11
  4480. .nr VS 11
  4481. .nr PS 9
  4482. .TS
  4483. center box;
  4484. lw(228p) .
  4485. TEST NUMBER:\ 3.3
  4486. _
  4487. .T&
  4488. lw(228p) .
  4489. REFERENCE:\ Q.724 \(sc 1.14
  4490. _
  4491. .T&
  4492. lw(228p) .
  4493. TITLE:\ Normal call release
  4494. _
  4495. .T&
  4496. lw(228p) .
  4497.  {
  4498. SUBTITLE:\ Calling party clears after answer
  4499.  }
  4500. _
  4501. .T&
  4502. lw(228p) .
  4503.  {
  4504. PURPOSE:\ To verify that the calling party can successfully
  4505. release a call in the speech state
  4506.  }
  4507. _
  4508. .T&
  4509. lw(228p) .
  4510.  {
  4511. PRE\(hyTEST CONDITIONS:\ Called termination is free
  4512.  }
  4513. _
  4514. .T&
  4515. cw(72p) | cw(84p) | cw(72p) .
  4516. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4517. _
  4518. .T&
  4519. lw(228p) .
  4520. EXPECTED MESSAGE SEQUENCE:
  4521. .T&
  4522. lw(72p) | lw(84p) | lw(72p) .
  4523. SP\ \ A        SP\ \ B
  4524. .T&
  4525. lw(72p) | cw(84p) | lw(72p) .
  4526. IAM    ------------------------->    
  4527. .T&
  4528. lw(72p) | cw(84p) | lw(72p) .
  4529.     <-------------------------    ACM
  4530. .T&
  4531. lw(72p) | cw(84p) | lw(72p) .
  4532.      {
  4533. \f | | fR
  4534. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  4535.  }    Ringing tone
  4536. .T&
  4537. lw(72p) | cw(84p) | lw(72p) .
  4538.     <-------------------------    ANC
  4539. .T&
  4540. lw(72p) | cw(84p) | lw(72p) .
  4541. Speech     {
  4542. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  4543.  }    Speech
  4544. .T&
  4545. lw(72p) | cw(84p) | lw(72p) .
  4546. CLF    ------------------------->    
  4547. .T&
  4548. lw(72p) | cw(84p) | lw(72p) .
  4549.     <-------------------------    RLG
  4550. _
  4551. .T&
  4552. lw(72p) | cw(84p) | lw(72p) .
  4553. TEST DESCRIPTION        
  4554. _
  4555. .T&
  4556. cw(18p) | lw(210p) .
  4557. 1.     {
  4558. Make a call from SP A to SP B.
  4559. Record the message sequence using a signal monitor.
  4560.  }
  4561. .T&
  4562. cw(18p) | lw(210p) .
  4563. 2.     {
  4564. CHECK A:
  4565. IS RINGING TONE HEARD? |  |  |  |  |  | 
  4566.  }
  4567. .T&
  4568. cw(18p) | lw(210p) .
  4569. 3.     {
  4570. The called party should answer the call.
  4571.  }
  4572. .T&
  4573. cw(18p) | lw(210p) .
  4574. 4.     {
  4575. CHECK B:
  4576. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  4577.  }
  4578. .T&
  4579. cw(18p) | lw(210p) .
  4580. 5.     {
  4581. The calling party should clear the call.
  4582.  }
  4583. .T&
  4584. cw(18p) | lw(210p) .
  4585. 6.     {
  4586. CHECK C:
  4587. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  4588.  }
  4589. .T&
  4590. cw(18p) | lw(210p) .
  4591. 7.     {
  4592. CHECK D:
  4593. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4594.  }
  4595. .T&
  4596. cw(18p) | lw(210p) .
  4597. 8.     {
  4598. For validation testing this test should be repeated in the reverse
  4599. direction.
  4600.  }
  4601. _
  4602. .TE
  4603. .nr PS 9
  4604. .RT
  4605. .ad r
  4606. \fBTableau [T30.783], p.\fR 
  4607. .sp 1P
  4608. .RT
  4609. .ad b
  4610. .RT
  4611. .LP
  4612. .bp
  4613. .ce
  4614. \fBH.T. [T31.783]\fR 
  4615. .ce
  4616. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4617. .ps 9
  4618. .vs 11
  4619. .nr VS 11
  4620. .nr PS 9
  4621. .TS
  4622. center box;
  4623. lw(228p) .
  4624. TEST NUMBER:\ 3.4
  4625. _
  4626. .T&
  4627. lw(228p) .
  4628. REFERENCE:\ Q.724 \(sc 1.14
  4629. _
  4630. .T&
  4631. lw(228p) .
  4632. TITLE:\ Normal call release
  4633. _
  4634. .T&
  4635. lw(228p) .
  4636.  {
  4637. SUBTITLE:\ Called party clears 
  4638.  }
  4639. _
  4640. .T&
  4641. lw(228p) .
  4642.  {
  4643. PURPOSE:\ To verify that the calling party can successfully
  4644. release a call in the clear back state
  4645.  }
  4646. _
  4647. .T&
  4648. lw(228p) .
  4649.  {
  4650. PRE\(hyTEST CONDITIONS:\ Called termination is free
  4651.  }
  4652. _
  4653. .T&
  4654. cw(72p) | cw(84p) | cw(72p) .
  4655. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4656. _
  4657. .T&
  4658. lw(228p) .
  4659. EXPECTED MESSAGE SEQUENCE:
  4660. .T&
  4661. lw(72p) | lw(84p) | lw(72p) .
  4662. SP\ \ A        SP\ \ B
  4663. .T&
  4664. lw(72p) | cw(84p) | lw(72p) .
  4665. IAM    ------------------------->    
  4666. .T&
  4667. lw(72p) | cw(84p) | lw(72p) .
  4668.     <-------------------------    ACM
  4669. .T&
  4670. lw(72p) | cw(84p) | lw(72p) .
  4671.      {
  4672. \f | | fR
  4673. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  4674.  }    Ringing tone
  4675. .T&
  4676. lw(72p) | cw(84p) | lw(72p) .
  4677.     <-------------------------    ANC
  4678. .T&
  4679. lw(72p) | cw(84p) | lw(72p) .
  4680. Speech     {
  4681. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  4682.  }    Speech
  4683. .T&
  4684. lw(72p) | cw(84p) | lw(72p) .
  4685.     <-------------------------    CBK
  4686. .T&
  4687. lw(72p) | cw(84p) | lw(72p) .
  4688. CLF    ------------------------->    
  4689. .T&
  4690. lw(72p) | cw(84p) | lw(72p) .
  4691.     <-------------------------    RLG
  4692. _
  4693. .T&
  4694. lw(72p) | cw(84p) | lw(72p) .
  4695. TEST DESCRIPTION        
  4696. _
  4697. .T&
  4698. cw(18p) | lw(210p) .
  4699. 1.     {
  4700. Make a call from SP A to SP B.
  4701. Record the message sequence using a signal monitor.
  4702.  }
  4703. .T&
  4704. cw(18p) | lw(210p) .
  4705. 2.     {
  4706. CHECK A:
  4707. IS RINGING TONE HEARD? |  |  |  |  |  | 
  4708.  }
  4709. .T&
  4710. cw(18p) | lw(210p) .
  4711. 3.     {
  4712. The called party should answer the call.
  4713.  }
  4714. .T&
  4715. cw(18p) | lw(210p) .
  4716. 4.     {
  4717. CHECK B:
  4718. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  4719.  }
  4720. .T&
  4721. cw(18p) | lw(210p) .
  4722. 5.     {
  4723. The called party should clear the call.
  4724.  }
  4725. .T&
  4726. cw(18p) | lw(210p) .
  4727. 6.     {
  4728. The calling party should clear the call.
  4729.  }
  4730. .T&
  4731. cw(18p) | lw(210p) .
  4732. 7.     {
  4733. CHECK C:
  4734. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  4735.  }
  4736. .T&
  4737. cw(18p) | lw(210p) .
  4738. 8.     {
  4739. CHECK D:
  4740. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4741.  }
  4742. .T&
  4743. cw(18p) | lw(210p) .
  4744. 9.     {
  4745. For validation testing repeat this test in the reverse
  4746. direction.
  4747.  }
  4748. _
  4749. .TE
  4750. .nr PS 9
  4751. .RT
  4752. .ad r
  4753. \fBTableau [T31.783], p.\fR 
  4754. .sp 1P
  4755. .RT
  4756. .ad b
  4757. .RT
  4758. .LP
  4759. .bp
  4760. .ce
  4761. \fBH.T. [T32.783]\fR 
  4762. .ce
  4763. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4764. .ps 9
  4765. .vs 11
  4766. .nr VS 11
  4767. .nr PS 9
  4768. .TS
  4769. center box;
  4770. lw(228p) .
  4771. TEST NUMBER:\ 3.5
  4772. _
  4773. .T&
  4774. lw(228p) .
  4775. REFERENCE:\ Q.724 \(sc 1.14
  4776. _
  4777. .T&
  4778. lw(228p) .
  4779. TITLE:\ Normal call release
  4780. _
  4781. .T&
  4782. lw(228p) .
  4783.  {
  4784. SUBTITLE:\ Called party clears and reanswers
  4785.  }
  4786. _
  4787. .T&
  4788. lw(228p) .
  4789.  {
  4790. PURPOSE:\ To verify that the called subscriber can successfully
  4791. clear and reanswer a call in the speech state
  4792.  }
  4793. _
  4794. .T&
  4795. lw(228p) .
  4796.  {
  4797. PRE\(hyTEST CONDITIONS:\ Called termination is free
  4798.  }
  4799. _
  4800. .T&
  4801. cw(72p) | cw(84p) | cw(72p) .
  4802. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  4803. _
  4804. .T&
  4805. lw(228p) .
  4806. EXPECTED MESSAGE SEQUENCE:
  4807. .T&
  4808. lw(72p) | lw(84p) | lw(72p) .
  4809. SP\ \ A        SP\ \ B
  4810. .T&
  4811. lw(72p) | cw(84p) | lw(72p) .
  4812. IAM    ------------------------->    
  4813. .T&
  4814. lw(72p) | cw(84p) | lw(72p) .
  4815.     <-------------------------    ACM
  4816. .T&
  4817. lw(72p) | cw(84p) | lw(72p) .
  4818.      {
  4819. \f | | fR
  4820. \(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy\(hy
  4821.  }    Ringing tone
  4822. .T&
  4823. lw(72p) | cw(84p) | lw(72p) .
  4824.     <-------------------------    ANC
  4825. .T&
  4826. lw(72p) | cw(84p) | lw(72p) .
  4827. Speech     {
  4828. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  4829.  }    Speech
  4830. .T&
  4831. lw(72p) | cw(84p) | lw(72p) .
  4832.     <-------------------------    CBK
  4833. .T&
  4834. lw(72p) | cw(84p) | lw(72p) .
  4835.     <-------------------------    RAN
  4836. .T&
  4837. lw(72p) | cw(84p) | lw(72p) .
  4838. Speech     {
  4839. \(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em\(em
  4840.  }    Speech
  4841. .T&
  4842. lw(72p) | cw(84p) | lw(72p) .
  4843. CLF    ------------------------->    
  4844. .T&
  4845. lw(72p) | cw(84p) | lw(72p) .
  4846.     <-------------------------    RLG
  4847. _
  4848. .T&
  4849. lw(72p) | cw(84p) | lw(72p) .
  4850. TEST DESCRIPTION        
  4851. _
  4852. .T&
  4853. cw(18p) | lw(210p) .
  4854. \ 1.     {
  4855. Make a call from SP A to SP B.
  4856. Record the message sequence using a signal monitor.
  4857.  }
  4858. .T&
  4859. cw(18p) | lw(210p) .
  4860. \ 2.     {
  4861. CHECK A:
  4862. IS RINGING TONE HEARD? |  |  |  |  |  | 
  4863.  }
  4864. .T&
  4865. cw(18p) | lw(210p) .
  4866. \ 3.     {
  4867. The called party should answer the call.
  4868.  }
  4869. .T&
  4870. cw(18p) | lw(210p) .
  4871. \ 4.     {
  4872. CHECK B:
  4873. IS SPEECH POSSIBLE? |  |  |  |  |  | 
  4874.  }
  4875. .T&
  4876. cw(18p) | lw(210p) .
  4877. \ 5.     {
  4878. The called party should clear the call.
  4879.  }
  4880. .T&
  4881. cw(18p) | lw(210p) .
  4882. \ 6.     {
  4883. The called party should reanswer the call.
  4884.  }
  4885. .T&
  4886. cw(18p) | lw(210p) .
  4887. \ 7.     {
  4888. CHECK C:
  4889. IS SPEECH STILL POSSIBLE? |  |  |  |  |  | 
  4890. \fR
  4891.  }
  4892. .T&
  4893. cw(18p) | lw(210p) .
  4894. \ 8.     {
  4895. The calling party should clear the call.
  4896.  }
  4897. .T&
  4898. cw(18p) | lw(210p) .
  4899. \ 9.     {
  4900. CHECK D:
  4901. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  4902.  }
  4903. .T&
  4904. cw(18p) | lw(210p) .
  4905. 10.     {
  4906. CHECK E:
  4907. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  4908.  }
  4909. .T&
  4910. cw(18p) | lw(210p) .
  4911. 11.     {
  4912. For validation testing repeat this test in the reverse
  4913. direction.
  4914.  }
  4915. _
  4916. .TE
  4917. .nr PS 9
  4918. .RT
  4919. .ad r
  4920. \fBTableau [T32.783], p.\fR 
  4921. .sp 1P
  4922. .RT
  4923. .ad b
  4924. .RT
  4925. .LP
  4926. .bp
  4927. .ce
  4928. \fBH.T. [T33.783]\fR 
  4929. .ce
  4930. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  4931. .ps 9
  4932. .vs 11
  4933. .nr VS 11
  4934. .nr PS 9
  4935. .TS
  4936. center box;
  4937. lw(228p) .
  4938. TEST NUMBER:\ 4.1.1
  4939. _
  4940. .T&
  4941. lw(228p) .
  4942. REFERENCE:\ Q.724 \(sc 1.8
  4943. _
  4944. .T&
  4945. lw(228p) .
  4946. TITLE:\ SEC
  4947. _
  4948. .T&
  4949. lw(228p) .
  4950. SUBTITLE:\ SEC received
  4951. _
  4952. .T&
  4953. lw(228p) .
  4954.  {
  4955. PURPOSE:
  4956. To verify the call will be immediately released by the
  4957. outgoing signalling point if a switching equipment congestion
  4958. signal is received and the correct indication is given to the
  4959. calling party
  4960.  }
  4961. _
  4962. .T&
  4963. lw(228p) .
  4964.  {
  4965. PRE\(hyTEST CONDITIONS:
  4966. Arrange the data in signalling point B
  4967. such that switching equipment congestion is returned to the
  4968. request
  4969.  }
  4970. _
  4971. .T&
  4972. cw(72p) | cw(84p) | cw(72p) .
  4973. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  4974. _
  4975. .T&
  4976. lw(228p) .
  4977. EXPECTED MESSAGE SEQUENCE:
  4978. .T&
  4979. lw(72p) | lw(84p) | lw(72p) .
  4980. SP\ \ A        SP\ \ B
  4981. .T&
  4982. lw(72p) | cw(84p) | lw(72p) .
  4983. IAM    ------------------------->    
  4984. .T&
  4985. lw(72p) | cw(84p) | lw(72p) .
  4986.     <-------------------------    SEC
  4987. .T&
  4988. lw(72p) | cw(84p) | lw(72p) .
  4989. CLF    ------------------------->    
  4990. .T&
  4991. lw(72p) | cw(84p) | lw(72p) .
  4992.     <-------------------------    RLG
  4993. _
  4994. .T&
  4995. lw(72p) | cw(84p) | lw(72p) .
  4996. TEST DESCRIPTION        
  4997. _
  4998. .T&
  4999. cw(18p) | lw(210p) .
  5000. 1.     {
  5001. Attempt to make a call from SP A to SP B.
  5002. Record the message sequence with a signal monitor.
  5003.  }
  5004. .T&
  5005. cw(18p) | lw(210p) .
  5006. 2.     {
  5007. CHECK A:
  5008. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED TO THE
  5009. CALLING PARTY? |  |  |  |  |  | 
  5010.  }
  5011. .T&
  5012. cw(18p) | lw(210p) .
  5013. 3.     {
  5014. CHECK B:
  5015. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  5016.  }
  5017. .T&
  5018. cw(18p) | lw(210p) .
  5019. 4.     {
  5020. CHECK C:
  5021. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  5022.  }
  5023. .T&
  5024. cw(18p) | lw(210p) .
  5025.      {
  5026. \fINote\fR
  5027. \ \(em\ It may not be possible to confirm that the appropriate tone is
  5028. returned to the calling party. In this case it must be verified that the
  5029. signalling point under test retransmits the signal
  5030. received.
  5031.  }
  5032. _
  5033. .TE
  5034. .nr PS 9
  5035. .RT
  5036. .ad r
  5037. \fBTableau [T33.783], p.\fR 
  5038. .sp 1P
  5039. .RT
  5040. .ad b
  5041. .RT
  5042. .LP
  5043. .bp
  5044. .ce
  5045. \fBH.T. [T34.783]\fR 
  5046. .ce
  5047. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5048. .ps 9
  5049. .vs 11
  5050. .nr VS 11
  5051. .nr PS 9
  5052. .TS
  5053. center box;
  5054. lw(228p) .
  5055. TEST NUMBER:\ 4.1.2
  5056. _
  5057. .T&
  5058. lw(228p) .
  5059. REFERENCE:\ Q.724 \(sc 1.8
  5060. _
  5061. .T&
  5062. lw(228p) .
  5063. TITLE:\ SEC
  5064. _
  5065. .T&
  5066. lw(228p) .
  5067. SUBTITLE:\ SEC sent
  5068. _
  5069. .T&
  5070. lw(228p) .
  5071.  {
  5072. PURPOSE:\ To verify that SP A is able to generate a
  5073. switching equipment congestion message
  5074.  }
  5075. _
  5076. .T&
  5077. lw(228p) .
  5078.  {
  5079. PRE\(hyTEST CONDITIONS:
  5080. Arrange the data in SP A such that
  5081. switching equipment congestion is returned to the call
  5082. request
  5083.  }
  5084. _
  5085. .T&
  5086. cw(72p) | cw(84p) | cw(72p) .
  5087. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5088. _
  5089. .T&
  5090. lw(228p) .
  5091. EXPECTED MESSAGE SEQUENCE:
  5092. .T&
  5093. lw(72p) | lw(84p) | lw(72p) .
  5094. SP\ \ A        SP\ \ B
  5095. .T&
  5096. lw(72p) | cw(84p) | lw(72p) .
  5097.     <-------------------------    IAM
  5098. .T&
  5099. lw(72p) | cw(84p) | lw(72p) .
  5100. SEC    ------------------------->    
  5101. .T&
  5102. lw(72p) | cw(84p) | lw(72p) .
  5103.     <-------------------------    CLF
  5104. .T&
  5105. lw(72p) | cw(84p) | lw(72p) .
  5106. RLG    ------------------------->    
  5107. _
  5108. .T&
  5109. lw(72p) | cw(84p) | lw(72p) .
  5110. TEST DESCRIPTION        
  5111. _
  5112. .T&
  5113. cw(18p) | lw(210p) .
  5114. 1.     {
  5115. Attempt to make a call from SP B to SP A.
  5116. Record the message sequence with a signal monitor.
  5117.  }
  5118. .T&
  5119. cw(18p) | lw(210p) .
  5120. 2.     {
  5121. CHECK A:
  5122. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED TO THE
  5123. CALLING PARTY? |  |  |  |  |  | 
  5124.  }
  5125. .T&
  5126. cw(18p) | lw(210p) .
  5127. 3.     {
  5128. CHECK B:
  5129. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  5130.  }
  5131. .T&
  5132. cw(18p) | lw(210p) .
  5133. 4.     {
  5134. CHECK C:
  5135. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  5136.  }
  5137. .T&
  5138. cw(18p) | lw(210p) .
  5139.      {
  5140. \fINote\fR
  5141. \ \(em\ It may not be possible to confirm that the appropriate tone is
  5142. returned to the calling party. In this case it must be verified that
  5143. the signalling point under test retransmits the signal
  5144. received.
  5145.  }
  5146. _
  5147. .TE
  5148. .nr PS 9
  5149. .RT
  5150. .ad r
  5151. \fBTableau [T34.783], p.\fR 
  5152. .sp 1P
  5153. .RT
  5154. .ad b
  5155. .RT
  5156. .LP
  5157. .bp
  5158. .ce
  5159. \fBH.T. [T35.783]\fR 
  5160. .ce
  5161. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5162. .ps 9
  5163. .vs 11
  5164. .nr VS 11
  5165. .nr PS 9
  5166. .TS
  5167. center box;
  5168. lw(228p) .
  5169. TEST NUMBER:\ 4.2.1
  5170. _
  5171. .T&
  5172. lw(228p) .
  5173. REFERENCE:\ Q.724 \(sc 1.8
  5174. _
  5175. .T&
  5176. lw(228p) .
  5177. TITLE:\ CGC
  5178. _
  5179. .T&
  5180. lw(228p) .
  5181. SUBTITLE:\ CGC received
  5182. _
  5183. .T&
  5184. lw(228p) .
  5185.  {
  5186. PURPOSE:
  5187. To verify that a call will be immediately released by the
  5188. outgoing signalling point if a\fR
  5189. circuit group congestion signal is received and the correct indication is
  5190. given to the calling party
  5191.  }
  5192. _
  5193. .T&
  5194. lw(228p) .
  5195.  {
  5196. PRE\(hyTEST CONDITIONS:
  5197. Arrange the data in signalling point B
  5198. such that a circuit group congestion signal is returned to the
  5199. call request
  5200.  }
  5201. _
  5202. .T&
  5203. cw(72p) | cw(84p) | cw(72p) .
  5204. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5205. _
  5206. .T&
  5207. lw(228p) .
  5208. EXPECTED MESSAGE SEQUENCE:
  5209. .T&
  5210. lw(72p) | lw(84p) | lw(72p) .
  5211. SP\ \ A        SP\ \ B
  5212. .T&
  5213. lw(72p) | cw(84p) | lw(72p) .
  5214. IAM    ------------------------->    
  5215. .T&
  5216. lw(72p) | cw(84p) | lw(72p) .
  5217.     <-------------------------    CGC
  5218. .T&
  5219. lw(72p) | cw(84p) | lw(72p) .
  5220. CLF    ------------------------->    
  5221. .T&
  5222. lw(72p) | cw(84p) | lw(72p) .
  5223.     <-------------------------    RLG
  5224. _
  5225. .T&
  5226. lw(72p) | cw(84p) | lw(72p) .
  5227. TEST DESCRIPTION        
  5228. _
  5229. .T&
  5230. cw(18p) | lw(210p) .
  5231. 1.     {
  5232. Attempt to make a call from SP A to SP B.
  5233. Record the message sequence using a signal monitor.
  5234.  }
  5235. .T&
  5236. cw(18p) | lw(210p) .
  5237. 2.     {
  5238. CHECK A:
  5239. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED TO THE
  5240. CALLING PARTY? |  |  |  |  |  | 
  5241.  }
  5242. .T&
  5243. cw(18p) | lw(210p) .
  5244. 3.     {
  5245. CHECK B:
  5246. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  5247.  }
  5248. .T&
  5249. cw(18p) | lw(210p) .
  5250. 4.     {
  5251. CHECK C:
  5252. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  5253.  }
  5254. .T&
  5255. cw(18p) | lw(210p) .
  5256.      {
  5257. \fINote\ 1\fR
  5258. \ \(em\ An address complete signal (without subscriber free)
  5259. may be sent in the backward direction before a CGC signal is sent. 
  5260.  }
  5261. .T&
  5262. cw(18p) | lw(210p) .
  5263.      {
  5264. \fINote\ 2\fR
  5265. \ \(em\ It may not be possible to confirm that the appropriate tone
  5266. is returned to the calling party. In this case it must be verified that
  5267. the signalling point under test retransmits the signal
  5268. received.
  5269.  }
  5270. _
  5271. .TE
  5272. .nr PS 9
  5273. .RT
  5274. .ad r
  5275. \fBTableau [T35.783], p.\fR 
  5276. .sp 1P
  5277. .RT
  5278. .ad b
  5279. .RT
  5280. .LP
  5281. .bp
  5282. .ce
  5283. \fBH.T. [T36.783]\fR 
  5284. .ce
  5285. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5286. .ps 9
  5287. .vs 11
  5288. .nr VS 11
  5289. .nr PS 9
  5290. .TS
  5291. center box;
  5292. lw(228p) .
  5293. TEST NUMBER:\ 4.2.2
  5294. _
  5295. .T&
  5296. lw(228p) .
  5297. REFERENCE:\ Q.724 \(sc 1.8
  5298. _
  5299. .T&
  5300. lw(228p) .
  5301. TITLE:\ CGC
  5302. _
  5303. .T&
  5304. lw(228p) .
  5305. SUBTITLE:\ CGC sent
  5306. _
  5307. .T&
  5308. lw(228p) .
  5309.  {
  5310. PURPOSE:\ To verify that SP A is able to generate a
  5311. circuit group congestion signal
  5312.  }
  5313. _
  5314. .T&
  5315. lw(228p) .
  5316.  {
  5317. PRE\(hyTEST CONDITIONS:
  5318. Arrange the data in signalling point A
  5319. such that a circuit group congestion signal is returned to the
  5320. call request
  5321.  }
  5322. _
  5323. .T&
  5324. cw(72p) | cw(84p) | cw(72p) .
  5325. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5326. _
  5327. .T&
  5328. lw(228p) .
  5329. EXPECTED MESSAGE SEQUENCE:
  5330. .T&
  5331. lw(72p) | lw(84p) | lw(72p) .
  5332. SP\ \ A        SP\ \ B
  5333. .T&
  5334. lw(72p) | cw(84p) | lw(72p) .
  5335.     <-------------------------    IAM
  5336. .T&
  5337. lw(72p) | cw(84p) | lw(72p) .
  5338. CGC    ------------------------->    
  5339. .T&
  5340. lw(72p) | cw(84p) | lw(72p) .
  5341.     <-------------------------    CLF
  5342. .T&
  5343. lw(72p) | cw(84p) | lw(72p) .
  5344. RLG    ------------------------->    
  5345. _
  5346. .T&
  5347. lw(72p) | cw(84p) | lw(72p) .
  5348. TEST DESCRIPTION        
  5349. _
  5350. .T&
  5351. cw(18p) | lw(210p) .
  5352. 1.     {
  5353. Attempt to make a call from SP B to SP A.
  5354. Record the message sequence using a signal monitor.
  5355.  }
  5356. .T&
  5357. cw(18p) | lw(210p) .
  5358. 2.     {
  5359. CHECK A:
  5360. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED TO THE
  5361. CALLING PARTY? |  |  |  |  |  | 
  5362.  }
  5363. .T&
  5364. cw(18p) | lw(210p) .
  5365. 3.     {
  5366. CHECK B:
  5367. IS THE CIRCUIT IDLE? |  |  |  |  |  | 
  5368.  }
  5369. .T&
  5370. cw(18p) | lw(210p) .
  5371. 4.     {
  5372. CHECK C:
  5373. WAS THE MESSAGE SEQUENCE AS ABOVE? |  |  |  |  |  | 
  5374.  }
  5375. .T&
  5376. cw(18p) | lw(210p) .
  5377.      {
  5378. \fINote\ 1\fR
  5379. \ \(em\ An address complete signal (without subscriber free)
  5380. may be sent in the backward direction before a CGC signal is
  5381. sent.
  5382.  }
  5383. .T&
  5384. cw(18p) | lw(210p) .
  5385.      {
  5386. \fINote\ 2\fR
  5387. \ \(em\ It may not be possible to confirm that the appropriate tone
  5388. is returned to the calling party. In this case it must be
  5389. verified that the signalling point under test retransmits the
  5390. signal received.
  5391.  }
  5392. _
  5393. .TE
  5394. .nr PS 9
  5395. .RT
  5396. .ad r
  5397. \fBTableau [T36.783], p.\fR 
  5398. .sp 1P
  5399. .RT
  5400. .ad b
  5401. .RT
  5402. .LP
  5403. .bp
  5404. .ce
  5405. \fBH.T. [T37.783]\fR 
  5406. .ce
  5407. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5408. .ps 9
  5409. .vs 11
  5410. .nr VS 11
  5411. .nr PS 9
  5412. .TS
  5413. center box;
  5414. lw(228p) .
  5415. TEST NUMBER:\ 4.3.1
  5416. _
  5417. .T&
  5418. lw(228p) .
  5419. REFERENCE:\ Q.\ 724 \(sc 1.8
  5420. _
  5421. .T&
  5422. lw(228p) .
  5423. TITLE:\ NNC
  5424. _
  5425. .T&
  5426. lw(228p) .
  5427. SUBTITLE:\ NNC received
  5428. _
  5429. .T&
  5430. lw(228p) .
  5431.  {
  5432. PURPOSE:
  5433. To verify that the call will be immediately released by the
  5434. outgoing signalling point if a national network congestion signal is
  5435. received and the correct indication is given to the calling
  5436. party
  5437.  }
  5438. _
  5439. .T&
  5440. lw(228p) .
  5441.  {
  5442. PRE\(hyTEST CONDITIONS:
  5443. Arrange the data in SP B such that a
  5444. national network congestion signal is returned to the call
  5445. request
  5446.  }
  5447. _
  5448. .T&
  5449. cw(72p) | cw(84p) | cw(72p) .
  5450. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5451. _
  5452. .T&
  5453. lw(228p) .
  5454. EXPECTED MESSAGE SEQUENCE:
  5455. .T&
  5456. lw(72p) | lw(84p) | lw(72p) .
  5457. SP\ \ A        SP\ \ B
  5458. .T&
  5459. lw(72p) | cw(84p) | lw(72p) .
  5460. IAM    ------------------------->    
  5461. .T&
  5462. lw(72p) | cw(84p) | lw(72p) .
  5463.     <-------------------------    NNC
  5464. .T&
  5465. lw(72p) | cw(84p) | lw(72p) .
  5466. CLF    ------------------------->    
  5467. .T&
  5468. lw(72p) | cw(84p) | lw(72p) .
  5469.     <-------------------------    RLG
  5470. _
  5471. .T&
  5472. lw(72p) | cw(84p) | lw(72p) .
  5473. TEST DESCRIPTION        
  5474. _
  5475. .T&
  5476. cw(18p) | lw(210p) .
  5477. 1.     {
  5478. Attempt to make a call from SP A to SP B.
  5479. Record the message sequence using a signal monitor.
  5480.  }
  5481. .T&
  5482. cw(18p) | lw(210p) .
  5483. 2.     {
  5484. CHECK A:
  5485. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED
  5486. TO THE CALLING PARTY? |  |  |  |  |  |  
  5487.  }
  5488. .T&
  5489. cw(18p) | lw(210p) .
  5490. 3.     {
  5491. CHECK B:
  5492. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  5493.  }
  5494. .T&
  5495. cw(18p) | lw(210p) .
  5496. 4.     {
  5497. CHECK C:
  5498. WAS THE MESSAGE SEQUENCE AS
  5499. ABOVE? |  |  |  |  |  | 
  5500.  }
  5501. .T&
  5502. cw(18p) | lw(210p) .
  5503.      {
  5504. \fINote\ 1\fR
  5505. \ \(em\ An address complete signal (without subscriber free) may be
  5506. sent in the backward direction before a NNC signal is sent.
  5507.  }
  5508. .T&
  5509. cw(18p) | lw(210p) .
  5510.      {
  5511. \fINote\ 2\fR
  5512. \ \(em\ It may not be possible to confirm that the appropriate tone
  5513. is returned to the calling party. In this case it must be verified that the
  5514. signalling point under test retransmits the signal received. 
  5515.  }
  5516. _
  5517. .TE
  5518. .nr PS 9
  5519. .RT
  5520. .ad r
  5521. \fBTableau [T37.783], p.\fR 
  5522. .sp 1P
  5523. .RT
  5524. .ad b
  5525. .RT
  5526. .LP
  5527. .bp
  5528. .ce
  5529. \fBH.T. [T38.783]\fR 
  5530. .ce
  5531. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5532. .ps 9
  5533. .vs 11
  5534. .nr VS 11
  5535. .nr PS 9
  5536. .TS
  5537. center box;
  5538. lw(228p) .
  5539. TEST NUMBER:\ 4.3.2
  5540. _
  5541. .T&
  5542. lw(228p) .
  5543. REFERENCE:\ Q.724 \(sc 1.8
  5544. _
  5545. .T&
  5546. lw(228p) .
  5547. TITLE:\ NNC
  5548. _
  5549. .T&
  5550. lw(228p) .
  5551. SUBTITLE:\ NNC sent
  5552. _
  5553. .T&
  5554. lw(228p) .
  5555.  {
  5556. PURPOSE:\ To verify that SP A is able to generate a national
  5557. network congestion signal
  5558.  }
  5559. _
  5560. .T&
  5561. lw(228p) .
  5562.  {
  5563. PRE\(hyTEST CONDITIONS:
  5564. Arrange the data in signalling point A such that
  5565. a national network congestion signal is returned to the call request,
  5566. where SP A is now an I/C exchange
  5567.  }
  5568. _
  5569. .T&
  5570. cw(72p) | cw(84p) | cw(72p) .
  5571. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5572. _
  5573. .T&
  5574. lw(228p) .
  5575. EXPECTED MESSAGE SEQUENCE:
  5576. .T&
  5577. lw(72p) | lw(84p) | lw(72p) .
  5578. SP\ \ A        SP\ \ B
  5579. .T&
  5580. lw(72p) | cw(84p) | lw(72p) .
  5581.     <-------------------------    IAM
  5582. .T&
  5583. lw(72p) | cw(84p) | lw(72p) .
  5584. NNC    ------------------------->    
  5585. .T&
  5586. lw(72p) | cw(84p) | lw(72p) .
  5587.     <-------------------------    CLF
  5588. .T&
  5589. lw(72p) | cw(84p) | lw(72p) .
  5590. RLG    ------------------------->    
  5591. _
  5592. .T&
  5593. lw(72p) | cw(84p) | lw(72p) .
  5594. TEST DESCRIPTION        
  5595. _
  5596. .T&
  5597. cw(18p) | lw(210p) .
  5598. 1.     {
  5599. Attempt to make a call from SP B to SP A.
  5600.  }
  5601. .T&
  5602. cw(18p) | lw(210p) .
  5603. 2.     {
  5604. CHECK A:
  5605. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED
  5606. TO THE CALLING PARTY? |  |  |  |  |  |  
  5607.  }
  5608. .T&
  5609. cw(18p) | lw(210p) .
  5610. 3.     {
  5611. CHECK B:
  5612. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  5613.  }
  5614. .T&
  5615. cw(18p) | lw(210p) .
  5616. 4.     {
  5617. CHECK C:
  5618. WAS THE MESSAGE SEQUENCE AS
  5619. ABOVE? |  |  |  |  |  | 
  5620.  }
  5621. .T&
  5622. cw(18p) | lw(210p) .
  5623.      {
  5624. \fINote\ 1\fR
  5625. \ \(em\ An address complete signal (without subscriber free) may be
  5626. sent in the backward direction before a NNC signal is sent.
  5627.  }
  5628. .T&
  5629. cw(18p) | lw(210p) .
  5630.      {
  5631. \fINote\ 2\fR
  5632. \ \(em\ It may not be possible to confirm that the appropriate tone
  5633. is returned to the calling party. In this case it must be verified that the
  5634. signalling point under test retransmits the signal received.
  5635.  }
  5636. _
  5637. .TE
  5638. .nr PS 9
  5639. .RT
  5640. .ad r
  5641. \fBTableau [T38.783], p.\fR 
  5642. .sp 1P
  5643. .RT
  5644. .ad b
  5645. .RT
  5646. .LP
  5647. .bp
  5648. .ce
  5649. \fBH.T. [T39.783]\fR 
  5650. .ce
  5651. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5652. .ps 9
  5653. .vs 11
  5654. .nr VS 11
  5655. .nr PS 9
  5656. .TS
  5657. center box;
  5658. lw(228p) .
  5659. TEST NUMBER:\ 4.4.1
  5660. _
  5661. .T&
  5662. lw(228p) .
  5663. REFERENCE:\ Q.724 \(sc 1.7
  5664. _
  5665. .T&
  5666. lw(228p) .
  5667. TITLE:\ ADI
  5668. _
  5669. .T&
  5670. lw(228p) .
  5671. SUBTITLE:\ ADI received
  5672. _
  5673. .T&
  5674. lw(228p) .
  5675.  {
  5676. PURPOSE:
  5677. To verify that on receipt of an address incomplete message
  5678. the call is immediately released and the correct indication given to
  5679. the calling party
  5680.  }
  5681. _
  5682. .T&
  5683. lw(228p) .
  5684.  {
  5685. PRE\(hyTEST CONDITIONS:
  5686. Signalling point B should be able to
  5687. determine that the proper number of digits has not been
  5688. received 
  5689.  }
  5690. _
  5691. .T&
  5692. cw(72p) | cw(84p) | cw(72p) .
  5693. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  5694. _
  5695. .T&
  5696. lw(228p) .
  5697. EXPECTED MESSAGE SEQUENCE:
  5698. .T&
  5699. lw(72p) | lw(84p) | lw(72p) .
  5700. SP\ \ A        SP\ \ B
  5701. .T&
  5702. lw(72p) | cw(84p) | lw(72p) .
  5703. IAM    ------------------------->    
  5704. .T&
  5705. lw(72p) | cw(84p) | lw(72p) .
  5706.     <-------------------------    ADI
  5707. .T&
  5708. lw(72p) | cw(84p) | lw(72p) .
  5709. CLF    ------------------------->    
  5710. .T&
  5711. lw(72p) | cw(84p) | lw(72p) .
  5712.     <-------------------------    RLG
  5713. _
  5714. .T&
  5715. lw(72p) | cw(84p) | lw(72p) .
  5716. TEST DESCRIPTION        
  5717. _
  5718. .T&
  5719. cw(18p) | lw(210p) .
  5720. 1.     {
  5721. Make a call from SP A to SP B, but do not enter the final digit.
  5722. Record the message sequence using a signal monitor.
  5723.  }
  5724. .T&
  5725. cw(18p) | lw(210p) .
  5726. 2.     {
  5727. CHECK A:
  5728. WAS THE CORRECT TONE OR ANNOUNCEMENT SENT TO THE
  5729. CALLING SUBSCRIBER? |  |  |  |  |  |  
  5730.  }
  5731. .T&
  5732. cw(18p) | lw(210p) .
  5733. 3.     {
  5734. CHECK B:
  5735. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  5736.  }
  5737. .T&
  5738. cw(18p) | lw(210p) .
  5739. 4.     {
  5740. CHECK C:
  5741. WAS THE MESSAGE SEQUENCE AS
  5742. ABOVE? |  |  |  |  |  | 
  5743.  }
  5744. .T&
  5745. cw(18p) | lw(210p) .
  5746.      {
  5747. \fINote\fR
  5748. \ \(em\ It may not be possible to confirm that the appropriate tone is
  5749. returned to the calling party. In this case it must be verified that the
  5750. signalling point under test retransmits the signal received.
  5751.  }
  5752. _
  5753. .TE
  5754. .nr PS 9
  5755. .RT
  5756. .ad r
  5757. \fBTableau [T39.783], p.\fR 
  5758. .sp 1P
  5759. .RT
  5760. .ad b
  5761. .RT
  5762. .LP
  5763. .bp
  5764. .ce
  5765. \fBH.T. [T40.783]\fR 
  5766. .ce
  5767. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5768. .ps 9
  5769. .vs 11
  5770. .nr VS 11
  5771. .nr PS 9
  5772. .TS
  5773. center box;
  5774. lw(228p) .
  5775. TEST NUMBER:\ 4.4.2
  5776. _
  5777. .T&
  5778. lw(228p) .
  5779. REFERENCE:\ Q.724 \(sc 1.7
  5780. _
  5781. .T&
  5782. lw(228p) .
  5783. TITLE:\ ADI
  5784. _
  5785. .T&
  5786. lw(228p) .
  5787. SUBTITLE:\ ADI sent
  5788. _
  5789. .T&
  5790. lw(228p) .
  5791.  {
  5792. PURPOSE:\ To verify that signalling point A is able to generate
  5793. an address incomplete signal
  5794.  }
  5795. _
  5796. .T&
  5797. lw(228p) .
  5798.  {
  5799. PRE\(hyTEST CONDITIONS:\ SP A should be able to determine that the
  5800. proper number of digits has not been received
  5801.  }
  5802. _
  5803. .T&
  5804. cw(72p) | cw(84p) | cw(72p) .
  5805. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT and CPT    TYPE OF SP:\ SP
  5806. _
  5807. .T&
  5808. lw(228p) .
  5809. EXPECTED MESSAGE SEQUENCE:
  5810. .T&
  5811. lw(72p) | lw(84p) | lw(72p) .
  5812. SP\ \ A        SP\ \ B
  5813. .T&
  5814. lw(72p) | cw(84p) | lw(72p) .
  5815.     <-------------------------    IAM
  5816. .T&
  5817. lw(72p) | cw(84p) | lw(72p) .
  5818. ADI    ------------------------->    
  5819. .T&
  5820. lw(72p) | cw(84p) | lw(72p) .
  5821.     <-------------------------    CLF
  5822. .T&
  5823. lw(72p) | cw(84p) | lw(72p) .
  5824. RLG    ------------------------->    
  5825. _
  5826. .T&
  5827. lw(72p) | cw(84p) | lw(72p) .
  5828. TEST DESCRIPTION        
  5829. _
  5830. .T&
  5831. cw(18p) | lw(210p) .
  5832. 1.     {
  5833. Make a call from SP B to SP A, but do not enter the final digit.
  5834. Record the message sequence using a signal monitor.
  5835.  }
  5836. .T&
  5837. cw(18p) | lw(210p) .
  5838. 2.     {
  5839. CHECK A:
  5840. WAS THE CORRECT TONE OR ANNOUNCEMENT SENT TO THE
  5841. CALLING SUBSCRIBER? |  |  |  |  |  |  
  5842.  }
  5843. .T&
  5844. cw(18p) | lw(210p) .
  5845. 3.     {
  5846. CHECK B:
  5847. IS THE CIRCUIT IDLE? |  |  |  |  |  |  
  5848.  }
  5849. .T&
  5850. cw(18p) | lw(210p) .
  5851. 4.     {
  5852. CHECK C:
  5853. WAS THE MESSAGE SEQUENCE AS
  5854. ABOVE? |  |  |  |  |  | 
  5855.  }
  5856. .T&
  5857. cw(18p) | lw(210p) .
  5858.      {
  5859. \fINote\fR
  5860. \ \(em\ It may not be possible to confirm that the appropriate tone is
  5861. returned to the calling party. In this case it must be verified that the
  5862. signalling point under test retransmits the signal received.
  5863.  }
  5864. _
  5865. .TE
  5866. .nr PS 9
  5867. .RT
  5868. .ad r
  5869. \fBTableau [T40.783], p.\fR 
  5870. .sp 1P
  5871. .RT
  5872. .ad b
  5873. .RT
  5874. .LP
  5875. .bp
  5876. .ce
  5877. \fBH.T. [T41.783]\fR 
  5878. .ce
  5879. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  5880. .ps 9
  5881. .vs 11
  5882. .nr VS 11
  5883. .nr PS 9
  5884. .TS
  5885. center box;
  5886. lw(228p) .
  5887. TEST NUMBER:\ 4.5.1
  5888. _
  5889. .T&
  5890. lw(228p) .
  5891. REFERENCE:\ Q.724 \(sc 6.3
  5892. _
  5893. .T&
  5894. lw(228p) .
  5895. TITLE:\ CFL
  5896. _
  5897. .T&
  5898. lw(228p) .
  5899. SUBTITLE:\ CFL received
  5900. _
  5901. .T&
  5902. lw(228p) .
  5903.  {
  5904. PURPOSE:
  5905. To verify that the call will be immediately released by the
  5906. outgoing signalling point if a call failure signal is
  5907. received and the correct indication is given to the calling
  5908. party
  5909.  }
  5910. _
  5911. .T&
  5912. lw(228p) .
  5913.  {
  5914. PRE\(hyTEST CONDITIONS:
  5915. Arrange the data in signalling point B such
  5916. that a call failure signal is returned to the call
  5917. request
  5918.  }
  5919. _
  5920. .T&
  5921. cw(72p) | cw(84p) | cw(72p) .
  5922. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  5923. _
  5924. .T&
  5925. lw(228p) .
  5926. EXPECTED MESSAGE SEQUENCE:
  5927. .T&
  5928. lw(72p) | lw(84p) | lw(72p) .
  5929. SP\ \ A        SP\ \ B
  5930. .T&
  5931. lw(72p) | cw(84p) | lw(72p) .
  5932. IAM    ------------------------->    
  5933. .T&
  5934. lw(72p) | cw(84p) | lw(72p) .
  5935.     <-------------------------    CFL
  5936. .T&
  5937. lw(72p) | cw(84p) | lw(72p) .
  5938. CLF    ------------------------->    
  5939. .T&
  5940. lw(72p) | cw(84p) | lw(72p) .
  5941.     <-------------------------    RLG
  5942. _
  5943. .T&
  5944. lw(72p) | cw(84p) | lw(72p) .
  5945. TEST DESCRIPTION        
  5946. _
  5947. .T&
  5948. cw(18p) | lw(210p) .
  5949. 1.     {
  5950. Attempt to make a call from SP A to SP B.
  5951. Record the message sequence using a signal monitor.
  5952.  }
  5953. .T&
  5954. cw(18p) | lw(210p) .
  5955. 2.     {
  5956. CHECK A:
  5957. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED
  5958. TO THE CALLING PARTY? |  |  |  |  |  |  
  5959.  }
  5960. .T&
  5961. cw(18p) | lw(210p) .
  5962. 3.     {
  5963. CHECK B:
  5964. IS THE CALL IDLE? |  |  |  |  |  |  
  5965.  }
  5966. .T&
  5967. cw(18p) | lw(210p) .
  5968. 4.     {
  5969. CHECK C:
  5970. WAS THE MESSAGE SEQUENCE AS
  5971. ABOVE? |  |  |  |  |  | 
  5972.  }
  5973. .T&
  5974. cw(18p) | lw(210p) .
  5975.      {
  5976. \fINote\ 1\fR
  5977. \ \(em\ An address complete signal may be
  5978. sent in the backward direction before a CFL signal is sent.
  5979.  }
  5980. .T&
  5981. cw(18p) | lw(210p) .
  5982.      {
  5983. \fINote\ 2\fR
  5984. \ \(em\ It may not be possible to confirm that the appropriate tone
  5985. is returned to the calling party. In this case it must be verified that the
  5986. signalling point under test retransmits the signal received.
  5987.  }
  5988. _
  5989. .TE
  5990. .nr PS 9
  5991. .RT
  5992. .ad r
  5993. \fBTableau [T41.783], p.\fR 
  5994. .sp 1P
  5995. .RT
  5996. .ad b
  5997. .RT
  5998. .LP
  5999. .bp
  6000. .ce
  6001. \fBH.T. [T42.783]\fR 
  6002. .ce
  6003. \fBTUP LEVEL 4 TEST SPECIFICATION\fR 
  6004. .ps 9
  6005. .vs 11
  6006. .nr VS 11
  6007. .nr PS 9
  6008. .TS
  6009. center box;
  6010. lw(228p) .
  6011. TEST NUMBER:\ 4.5.2
  6012. _
  6013. .T&
  6014. lw(228p) .
  6015. REFERENCE:\ Q.724 \(sc 6.3
  6016. _
  6017. .T&
  6018. lw(228p) .
  6019. TITLE:\ CFL
  6020. _
  6021. .T&
  6022. lw(228p) .
  6023. SUBTITLE:\ CFL sent
  6024. _
  6025. .T&
  6026. lw(228p) .
  6027.  {
  6028. PURPOSE:\ To verify that signalling point A is able to generate
  6029. a call failure signal
  6030.  }
  6031. _
  6032. .T&
  6033. lw(228p) .
  6034.  {
  6035. PRE\(hyTEST CONDITIONS:\ Arrange the data in SP A such that a
  6036. call failure signal is returned to the call
  6037. request
  6038.  }
  6039. _
  6040. .T&
  6041. cw(72p) | cw(84p) | cw(72p) .
  6042. CONFIGURATION:\ 1    TYPE OF TEST:\ VAT    TYPE OF SP:\ SP
  6043. _
  6044. .T&
  6045. lw(228p) .
  6046. EXPECTED MESSAGE SEQUENCE:
  6047. .T&
  6048. lw(72p) | lw(84p) | lw(72p) .
  6049. SP\ \ A        SP\ \ B
  6050. .T&
  6051. lw(72p) | cw(84p) | lw(72p) .
  6052.     <-------------------------    IAM
  6053. .T&
  6054. lw(72p) | cw(84p) | lw(72p) .
  6055. CFL    ------------------------->    
  6056. .T&
  6057. lw(72p) | cw(84p) | lw(72p) .
  6058.     <-------------------------    CLF
  6059. .T&
  6060. lw(72p) | cw(84p) | lw(72p) .
  6061. RLG    ------------------------->    
  6062. _
  6063. .T&
  6064. lw(72p) | cw(84p) | lw(72p) .
  6065. TEST DESCRIPTION        
  6066. _
  6067. .T&
  6068. cw(18p) | lw(210p) .
  6069. 1.     {
  6070. Attempt to make a call from SP B to SP A.
  6071. Record the message sequence using a signal monitor.
  6072.  }
  6073. .T&
  6074. cw(18p) | lw(210p) .
  6075. 2.     {
  6076. CHECK A:
  6077. IS THE APPROPRIATE TONE OR ANNOUNCEMENT RETURNED
  6078. TO THE CALLING PARTY? |  |  |  |  |  |  
  6079.  }
  6080. .T&
  6081. cw(18p) | lw(210p) .
  6082. 3.     {
  6083. CHECK B:
  6084. IS THE CALL IDLE? |  |  |  |  |  |  
  6085.  }
  6086. .T&
  6087. cw(18p) | lw(210p) .
  6088. 4.     {
  6089. CHECK C:
  6090. WAS THE MESSAGE SEQUENCE AS
  6091. ABOVE? |  |  |  |  |  | 
  6092.  }
  6093. .T&
  6094. cw(18p) | lw(210p) .
  6095.      {
  6096. \fINote\ 1\fR
  6097. \ \(em\ An address complete signal may be
  6098. sent in the backward direction before a CFL signal is sent. 
  6099.  }
  6100. .T&
  6101. cw(18p) | lw(210p) .
  6102.      {
  6103. \fINote\ 2\fR
  6104. \ \(em\ It may not be possible to confirm that the appropriate tone
  6105. is returned to the calling party. In this case it must be verified that the
  6106. signalling point under test retransmits the signal received. 
  6107.  }
  6108. _
  6109. .TE
  6110. .nr PS 9
  6111. .RT
  6112. .ad r
  6113. \fBTableau [T42.783], p.\fR 
  6114. .sp 1P
  6115. .RT
  6116. .ad b
  6117. .RT